verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 6TV · 3/2-Way Solenoid Valve

Airtac 6TV Solenoid Valve 6TV21008NCA050

Genuine AirTAC 3/2-way solenoid valve, order code 6TV21008NCA050 from the 6TV range. The options this code selects are decoded below; series data follow the official AirTAC catalog.

  • Body and port200 series, 1/4" PT
  • FunctionSingle solenoid, normally closed (10, NC)
  • Voltage and leadAC220V (A), 0.5 m lead
  • Function3/2-way solenoid valve
  • OperationPilot operated (solenoid)
  • 0500 seriesM5 supply, outlets and exhausts · 3.4 mm² (Cv 0.2)
$27.88 $35.38Save 21%
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 6TV body and port, function, voltage and lead on one page All 6TV codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 6TV Solenoid Valve 6TV21008NCA050

Sized for Cv 0.91 flow, the AirTAC 6TV21008NCA050 is a single-solenoid, normally closed 3/2-way solenoid valve with PT1/4 supply and outlet with a PT1/8 exhaust: the outlet stays shut off from supply until the coil is energized. The 200 series body passes 15.4 mm2 (Cv 0.91) and the 6TV210 weighs 90 g. The AC220V coil (code A) draws 1.1 VA, is class F insulated, plugs into its connector and responds in 0.05 s or less; the 050 code gives a 0.5 m lead.

AirTAC discontinued the 6TV series in January 2026 and has not named a replacement, so request a quote with the order code 6TV21008NCA050 and we will confirm whether this valve can still be supplied. The valve is pilot operated, with the pilot exhaust vented through the R port, and it can be piped directly or mounted on a 6TV200M manifold base. It works from 0.15 to 0.8 MPa (21-114 psi) on air filtered to 40 um, proof pressure 1.2 MPa, -20 to +70 C, at up to 5 cycles/s, with no lubrication needed.

Airtac 6TV Solenoid Valve 6TV21008NCA050 Technical Specifications

Order code6TV21008NCA050
Product3/2-Way Solenoid Valve
Body and port200 series, 1/4" PT
FunctionSingle solenoid, normally closed (10, NC)
Voltage and leadAC220V (A), 0.5 m lead
Function3/2-way solenoid valve
OperationPilot operated (solenoid)
0500 seriesM5 supply, outlets and exhausts · 3.4 mm² (Cv 0.2)
100 seriesM5 or PT1/8 supply, outlets and exhausts · 8.9 mm² (Cv 0.52)
200 seriesPT1/8 or PT1/4 supply and outlets, PT1/8 exhausts · 15.4 mm² (Cv 0.91)
300 seriesPT3/8 supply and outlets, PT1/4 exhausts · 38.4 mm² (Cv 2.26)
Weight6TV0510 28 g · 6TV0520 43 g · 6TV110 52 g · 6TV120 67 g · 6TV210 90 g · 6TV220 105 g · 6TV310 180 g · 6TV320 215 g
FluidAir (filtered by 40 µm element)
Operating pressure0.15 – 0.8 MPa (21 – 114 psi)
Proof pressure1.2 MPa (175 psi)
Temperature-20 to +70 °C
Max frequency5 cycles/s
BodyAluminum alloy
LubricationNot required
Coil voltagesAC220V, AC110V, DC24V, DC12V
Coil powerAC 1.1 VA · DC 0.7 W
Voltage toleranceAC +15% / -10%, DC ±10%
InsulationClass F, dust-protected
Electrical entryPlug-in connector
Response time0.05 s or less

Source: AirTAC 6TV series datasheet (airtac.com discontinued products), specifications and ordering code. AirTAC lists the 6TV series as discontinued (January 2026).

How to choose

Within this body, 6TV21008NOA050 is the normally open counterpart; 6TV22008A050 the double-solenoid version that holds its position; DC24V, AC110V and DC12V coils replace the A with B/C/F; 6TV21008NCA200 has the 2.0 m lead; the 1/8 port version is 6TV21006NCA050. Across the range, for more flow the 300 series passes 38.4 mm2 (Cv 2.26); for a smaller body the 100 series passes 8.9 mm2 (Cv 0.52). PT threads are standard here; G (BSPP) and NPT are marked G and T.

Applications

vertical_align_top

Single-acting cylinder drive

Energizing the coil from a 220 V AC control panel feeds the cylinder; with the coil off the outlet is vented through the exhaust.

speed

Medium cylinders

Cv 0.91 on PT1/4 ports feeds medium cylinders and blow nozzles.

build

Replacing valves on existing machines

Matches 6TV200 valves already installed on a 6TV200M base; the 0.5 m lead reaches a nearby terminal box.

FAQ

What are the key figures of the 6TV21008NCA050?

3/2-way, single-solenoid, normally closed; 200 series body with PT1/4 supply and outlet with a PT1/8 exhaust; effective area 15.4 mm2 (Cv 0.91); 0.15-0.8 MPa (21-114 psi), proof 1.2 MPa; -20 to +70 C; up to 5 cycles/s; AC220V coil, 1.1 VA, class F, plug-in; 0.5 m lead; response 0.05 s or less; 90 g.

Is the 6TV21008NCA050 still available?

AirTAC discontinued the 6TV series in January 2026 and has not named a replacement. Send a quote request with the exact code 6TV21008NCA050 and we will check whether the valve can still be supplied.