verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC 7V230C · Solenoid Valve

Airtac 7V Solenoid Valve 7V230C08A200

Genuine AirTAC solenoid valve, order code 7V230C08A200 from the 7V230C range. The options this code selects are decoded below; series data follow the official AirTAC catalog.

  • PortPT1/4
  • Coil voltageAC220V (A)
  • Lead wireLead 2.0 m (200)
  • Function5/3-way closed center (double solenoid, all ports blocked in the center position)
  • PortsPT1/4, Ø8 mm push-in (J08), Ø10 mm push-in (J10)
  • Exhaust portsPT1/8 on the PT1/4 version
$53.47 $60.97Save 12%
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every 7V230C port, coil voltage and lead wire on one page All 7V230C codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac 7V Solenoid Valve 7V230C08A200

With an AC220V coil and a 2.0 m lead, the AirTAC 7V230C08A200 is a 5/3-way closed-center solenoid valve with PT1/4 supply and outlet ports with PT1/8 exhausts. With both coils off the spool centers and blocks every port, holding a cylinder where it is. The catalog flow on PT1/4 is 10.8 mm2 (Cv 0.64). The AC220V coil (code A) draws 1.1 VA, is class F and dust-protected, responds in 0.05 s or less and plugs in horizontally or vertically; the 200 code gives a 2.0 m lead.

It is pilot operated from 0.2 to 0.8 MPa (29-114 psi) on air filtered to 40 um, proof pressure 1.2 MPa, -10 to +50 C, at up to 3 cycles/s, and weighs 145 g. The die-cast aluminum-alloy body collects the pilot exhaust and vents it through the R and S ports. No lubrication is needed; once lubricated air is used, keep using it with ISO VG32 oil.

Airtac 7V Solenoid Valve 7V230C08A200 Technical Specifications

Order code7V230C08A200
ProductSolenoid Valve
PortPT1/4
Coil voltageAC220V (A)
Lead wireLead 2.0 m (200)
Function5/3-way closed center (double solenoid, all ports blocked in the center position)
PortsPT1/4, Ø8 mm push-in (J08), Ø10 mm push-in (J10)
Exhaust portsPT1/8 on the PT1/4 version
Effective area10.8 mm² (Cv 0.64) on PT1/4 (catalog value for 7V230C)
Weight145 g
Max frequency3 cycles/s
FluidAir (filtered by 40 µm element)
PilotInternal
Operating pressure0.2 – 0.8 MPa (29 – 114 psi)
Proof pressure1.2 MPa (175 psi)
Temperature-10 to +50 °C
Coil powerAC 1.1 VA · DC 0.7 W
Voltage toleranceAC +15% / -10%, DC ±10%
InsulationClass F, dust-protected
BodyAluminum alloy
LubricationNot required

Source: AirTAC catalog P80, 7V series specifications and ordering code. Effective area is the catalog figure for the PT1/4 port.

How to choose

Within the 7V230C, DC24V, AC110V and DC12V coils replace the A with B/C/F; 7V230C08A050 has the 0.5 m lead; the other ports of this body are Dia 8 mm push-in (7V230CJ08A200) and Dia 10 mm push-in (7V230CJ10A200). The same body comes as 7V210, 7V220, 7V230E and 7V230P: 10 single solenoid, 20 double solenoid, 30C/30E/30P the 5/3-way centers. PT threads are standard; G (BSPP) and NPT are marked G and T at the end of the code. Several 7V200 valves can share a 7V200M manifold base of 1 to 20 stations.

Applications

pan_tool

Mid-stroke stop

Both coils off blocks all ports and holds the cylinder where it is.

precision_manufacturing

Machine pneumatics

Cv 0.64 on PT1/4 suits medium cylinders.

electrical_services

AC220V control circuits

The AC220V coil connects to a 220 V AC control panel; the 2.0 m lead plugs into the coil terminal.

FAQ

What are the key figures of the 7V230C08A200?

5/3-way closed-center solenoid valve, 7V200 series; PT1/4 ports; catalog flow 10.8 mm2 (Cv 0.64); 0.2-0.8 MPa (29-114 psi), proof 1.2 MPa; -10 to +50 C; up to 3 cycles/s; AC220V coil, 1.1 VA, class F; 2.0 m lead; response 0.05 s or less; 145 g.

What does the 7V230C08A200 do with the coils off?

With both coils off the spool centers and blocks every port, holding a cylinder where it is.