verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20006LC1W

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC20006LC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/8" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/8"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$69.51 $74.93Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20006LC1W

The AirTAC GFC series pairs a filter regulator with a separate lubricator in a two-piece set, delivering filtered, regulated, oil-misted compressed air from one installation. This GFC20006LC1W is the 200 size with a PT1/8 port, the low-pressure (L) regulator type, the 5 um fine filter element, the default differential-pressure drain, and an external round pressure gauge scaled in MPa. Maximum working pressure is 1.0 MPa (145 psi). As a low-pressure type its set pressure is limited to low-pressure duty; confirm the exact adjustment range with us. The polycarbonate bowls are rated -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The same set is available in 300, 400 and 600 sizes with larger ports, and options include automatic or manual drains, the 40 um standard element, square or round gauges in MPa, psi or bar scales, and G (BSPP) or NPT threads as catalogue choices. Flow is published as curves, not a single rated figure, so ask us to confirm flow and datasheet figures for your application.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20006LC1W Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20006LC1W
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/8" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20006LC1W

GFC200G-series two-unit set, 200 body — sets the port range.
06Port size PT1/8". This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-06 filter regulator and GL200-06 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · PT1/8" · 5 µm
One size upGFC300
Three-unit equivalentGC200-06
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20006LC1W Is Used

science

Analytical instrument air supply

Conditions the air feeding sampling valves and small actuators inside an analytical instrument, where the 5 um element keeps fine internal passages clean and the regulator holds a gentle low set pressure.

precision_manufacturing

Small-part sorting fixtures

Supplies delicate ejector and pusher cylinders on a small-part sorting fixture with clean, oil-misted, low-pressure air, monitored on the round MPa gauge.

engineering

Pneumatic component test rig

Feeds a bench test rig for valves and actuators, giving technicians fine-filtered, lubricated air at a stable low set pressure that is easy to read and repeat.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20006LC1W the Right Set?

The W in this code selects the 5 um element instead of the 40 um standard grade - pick it when downstream valves, cylinders or instruments are sensitive to finer particles. The L code selects the low-pressure regulator type for set points below the standard range; standard versions adjust 0.15-0.9 MPa (20-130 psi) with the differential-pressure drain this unit carries, and we confirm the L-type range on request. The 200 size with its PT1/8 port is the smallest step; move to GFC300 (1/4 in) and above for higher demand. This unit carries the external round MPa gauge, and PT is the standard thread with G (BSPP) or NPT orderable as options. Flow is published only as curves, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/8" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-06 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20006LC1W FAQ

Flow for the G series is published as curves rather than a single rated value, so we do not state a number on the page. Tell us your duty cycle and air demand, and we will confirm the flow for this 200 size with a PT1/8 port from the datasheet before you order.

This model's W code fits the 5 um fine element, the right choice for sensitive valves, small cylinders and instrument-grade circuits. The standard 40 um element (no W in the code) suits general plant circuits and holds up well where air quality demands are ordinary; both grades are catalogue options across the GFC family.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20006LC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC20006LC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.