verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC1WK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC1WK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$80.87 $86.56Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC1WK

The AirTAC GFC series is a two-unit air preparation set: a filter-regulator body plus a separate lubricator, covering filtration, pressure regulation and oil-mist lubrication together. This configuration, the GFC20008MC1WK, is the 200 size with a PT1/4 port. It carries a manual drain (M), the finer 5 um element (W), the external round gauge reading in MPa (C1), and the K code means a reverse/check valve is fitted so downstream pressure is held if the supply drops.

This is a genuine AirTAC part in the G range, which spans sizes 200 to 600 with increasing port and flow. Bowls on 200/300/400 sizes are polycarbonate. Medium is compressed air, maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C. Flow figures are published as curves rather than a single rating, so we confirm the datasheet numbers for your circuit on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC1WK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC1WK
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC1WK

GFC200G-series two-unit set, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · PT1/4" · 5 µm
One size upGFC300
Three-unit equivalentGC200-08
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC1WK Is Used

valve

Pilot-air supply to process valves

Held set pressure for the positioners and pilot solenoids on a process valve manifold, with lubricated air keeping the actuators smooth.

factory

Robotic end-effector grippers

Filtered 5 um air at regulated pressure feeding gripper cylinders on an assembly robot, with the check valve holding grip during supply dips.

engineering

Test-bench actuation skid

Stable, lubricated air for the clamp and lift cylinders on a leak-test or pressure-test bench in a production lab.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC1WK the Right Set?

Stay at 200/1/4" for compact circuits, or step to 300/400/600 as your demand rises. The check valve (K) is the decode to choose when you must hold a set pressure downstream through a supply dip - pick the plain variant if that is not wanted. The manual drain suits attended installations; automatic (A) or the differential-pressure default suit unattended ones. The 5 um element (W) protects sensitive valves better than the standard 40 um. The C1 round gauge reads MPa; psi and bar scales exist on other variants. PT is the standard thread, with G(BSPP) and NPT as catalogue options to order. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC1WK FAQ

AirTAC publishes G-series flow as curves, not as a single rated figure, so quoting one number would be misleading. Send us your working pressure and air demand and we will confirm the correct size from the datasheet on request before you order.

The K code means a reverse/check valve is fitted in the set, so downstream pressure is retained if the upstream supply falls. It is a real decode choice on the GFC: order the plain GFC20008MC1W if you do not need that hold-in behaviour, or this WK variant if you do.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC1WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC20008MC1WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.