The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC1WK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GFC series is a two-unit air preparation set: a filter-regulator body plus a separate lubricator, covering filtration, pressure regulation and oil-mist lubrication together. This configuration, the GFC20008MC1WK, is the 200 size with a PT1/4 port. It carries a manual drain (M), the finer 5 um element (W), the external round gauge reading in MPa (C1), and the K code means a reverse/check valve is fitted so downstream pressure is held if the supply drops.
This is a genuine AirTAC part in the G range, which spans sizes 200 to 600 with increasing port and flow. Bowls on 200/300/400 sizes are polycarbonate. Medium is compressed air, maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C. Flow figures are published as curves rather than a single rating, so we confirm the datasheet numbers for your circuit on request.
| Model | Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC1WK |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, MPa scale |
| Reflux valve | Fitted (reverse flow permitted) |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 1 | Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| K | Reverse-flow (reflux) valve fitted. |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/4" · 5 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-08 |
| Build order | Filter regulator first, lubricator last |
Held set pressure for the positioners and pilot solenoids on a process valve manifold, with lubricated air keeping the actuators smooth.
Filtered 5 um air at regulated pressure feeding gripper cylinders on an assembly robot, with the check valve holding grip during supply dips.
Stable, lubricated air for the clamp and lift cylinders on a leak-test or pressure-test bench in a production lab.
Stay at 200/1/4" for compact circuits, or step to 300/400/600 as your demand rises. The check valve (K) is the decode to choose when you must hold a set pressure downstream through a supply dip - pick the plain variant if that is not wanted. The manual drain suits attended installations; automatic (A) or the differential-pressure default suit unattended ones. The 5 um element (W) protects sensitive valves better than the standard 40 um. The C1 round gauge reads MPa; psi and bar scales exist on other variants. PT is the standard thread, with G(BSPP) and NPT as catalogue options to order. Because flow is published as curves rather than a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.
AirTAC publishes G-series flow as curves, not as a single rated figure, so quoting one number would be misleading. Send us your working pressure and air demand and we will confirm the correct size from the datasheet on request before you order.
The K code means a reverse/check valve is fitted in the set, so downstream pressure is retained if the upstream supply falls. It is a real decode choice on the GFC: order the plain GFC20008MC1W if you do not need that hold-in behaviour, or this WK variant if you do.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.