The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC2W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).
The AirTAC GFC series is a two-unit air preparation set: a filter-regulator body plus a separate lubricator, delivering filtration, pressure regulation and oil-mist lubrication together. This configuration, the GFC20008MC2W, is the 200 size with a PT1/4 port. The M code gives a manual drain on the filter bowl, the W code fits the finer 5 um filter element, and the C2 code adds the external round pressure gauge reading in psi.
This is a genuine AirTAC part in the G range, which spans sizes 200 to 600 with increasing port and flow. Bowls on 200/300/400 sizes are polycarbonate. Medium is compressed air, maximum inlet pressure is 1.0 MPa (145 psi), and the working temperature range is -5 to 70 C. Flow figures are published as curves rather than a single rating, so we confirm the datasheet numbers for your application on request.
| Model | Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC20008MC2W |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | PT1/4" (PT thread) |
| Filtering grade | 5 µm |
| Regulating range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Manual drain |
| Bowl material | PC |
| Pressure gauge | Fitted — round, psi scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| 08 | Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4". |
| M | Drain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| C | Gauge shape: Round. C is round, F is square. |
| 2 | Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar. |
| W | Filtering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-08 filter regulator and GL200-08 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · PT1/4" · 5 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-08 |
| Build order | Filter regulator first, lubricator last |
Finely filtered, regulated and lubricated air for the pneumatic actuators and valve arrays on an automated laboratory sampling station.
Clean 5 um air at a set pressure feeding the air bearings of a precision measuring or inspection table, with mist-free filtered supply upstream.
Prepared air for the vacuum generators and Z-axis cylinders on a PCB placement or test-head handling station.
Choose 200 with a 1/4" port for compact circuits, or step up to 300/400/600 as demand grows, since each step increases port size and flow capacity. The W code here fits the 5 um element, the grade to pick for valves, cylinders and instruments that need finer air than the standard 40 um. Manual drain means an operator bleeds the bowl; choose automatic (A) or the differential-pressure default for unattended service. The C2 round gauge reads in psi, convenient for psi-based settings; MPa and bar scales are on other variants. PT is the standard thread, with G(BSPP) and NPT as catalogue options to order. Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-08 filter regulator on its own.
We do not quote a single rated-flow number because AirTAC publishes G-series flow as curves and no single rating exists in our validated facts. Share your working pressure and demand and we will confirm the datasheet flow for your application on request before ordering.
Yes. The C2 code here means the external round gauge reading in psi is fitted. Other codes in the same GFC200-08 family give an MPa or bar scale, and the embedded square gauge is the default arrangement when no round gauge code appears - pick the variant that matches how your team sets pressure.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.