AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNW

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$57.06 $62.16Save 8% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNW

GFC200C06MNW is a two-piece AirTAC air-preparation set: a filter regulator plus a separate lubricator. The filter-regulator section removes water and particles down to the finer 5 um (W) grade and holds the downstream pressure you set (adjustable 0.05-0.9 MPa / 7-130 psi with this manual drain), while the lubricator meters oil mist into the line. The 200 size carries PT1/8 ports (PT thread as standard) and a manual-drain PC (polycarbonate) bowl; no gauge is supplied in this version. Maximum working pressure is 1.0 MPa (145 psi), operating range -5 to 70 C, mounting bracket included.

This is a genuine AirTAC part from the G-series, which spans sizes 200 to 600 with ports from 1/8 to 1 inch and a choice of drain type, filter grade, gauge and thread. AirTAC publishes flow as curves rather than one rated figure, so we confirm flow and other datasheet figures for your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNW
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNW

GFC200G-series two-unit set, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · See datasheet · 40 µm
One size upGFC300
Three-unit equivalentGC200-C0
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNW Is Used

science

Laboratory analyzer pneumatics

Supplies 5 um filtered, regulated and lubricated air to the sample-handling cylinders and dosing pumps on a laboratory analyzer.

view_module

Small-parts sorting gates

Conditions air driving the divert gates and ejector cylinders on a small-parts sorting module along a sorting conveyor.

tune

Printing press feed cylinders

Delivers set, filtered and oiled air to the paper-feed and ink-roller auxiliary cylinders on an offset printing press.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNW the Right Set?

Size 200 with PT1/8 ports suits compact circuits; step up to 300 (PT1/4), 400 (PT3/8) or 600 when the port size or air demand grows. The W in this code selects the 5 um element instead of the standard 40 um grade, a good move when finer particle removal matters. Draining is manual, so an operator drains the bowl periodically; automatic and differential-pressure drains are alternatives. No gauge is supplied, though square or round gauges with MPa, psi or bar scales can be ordered. PT is the standard thread, with G (BSPP) and NPT as catalogue options. Flow is published as curves rather than a single rating, so send us your demand figures and we will confirm sizing from the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNW FAQ

AirTAC does not publish a single rated flow figure for the G-series; flow is given as performance curves only. Tell us your line pressure and air demand and we will confirm the flow from the datasheet on request before you order.

The W in this code fits the 5 um grade, which removes finer particles than the standard 40 um element. Choose it where downstream equipment is sensitive to fine contamination; note it is a filtration choice only and does not change the regulator or lubricator function.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC200C06MNW and will confirm price, stock and lead time — usually within 7-8 hours.