verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNWK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNWK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$68.40 $73.79Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNWK

GFC200C06MNWK is an AirTAC G-series two-unit air-preparation set: a filter-regulator and a lubricator paired as one assembly, so a single mounting filters, regulates and lubricates the compressed air. This 200-size configuration is threaded PT1/8, drains its bowl manually, carries the fine 5 um (W) filter element, is supplied without a gauge, and has a reverse (check) valve fitted to block reverse flow through the set.

This is a genuine AirTAC part built on the 200 frame of a family that steps through 200, 300, 400 and 600 sizes. Max working pressure is 1.0 MPa (145 psi), the regulator adjusts 0.05-0.9 MPa (7-130 psi) with this manual-drain bowl, and the working temperature range is -5 to 70 C (non-freezing). Flow is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet numbers for your application.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNWK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNWK
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNWK

GFC200G-series two-unit set, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · See datasheet · 40 µm
One size upGFC300
Three-unit equivalentGC200-C0
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNWK Is Used

precision_manufacturing

Robotic gripper air prep

Filtering, regulating and lubricating the supply to gripper and tool-change valves on a robot assembly cell, with the fitted check valve blocking reverse flow toward the set.

build

CNC machining centre supply

Conditioning shop air before it reaches tool-clamp and chip-clearing cylinders on a CNC machining centre, with 5 um filtration protecting the finer pilot valves.

science

Lab automation skid

Supplying filtered, pressure-stabilised and lubricated air to actuated valves on a laboratory sample-handling skid, where manual draining suits attended daily operation.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNWK the Right Set?

The 200 size with PT1/8 ports suits compact supply points; step up to 300, 400 or 600 when the circuit needs larger ports and more flow. This version has a manual drain, the right choice where an operator attends the machine regularly; choose automatic or differential-pressure drain for unattended installations. The 5 um element here protects finer components than the standard 40 um grade, and the fitted check valve blocks reverse flow. Gauges can be specified if you want a visual setpoint, and G (BSPP) or NPT thread versions are catalogue options. Flow is published as curves, not a single rating, so send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNWK FAQ

AirTAC publishes flow for the G-series as curves, not as a single rated figure, so we do not quote one number here. Tell us your required flow and working pressure and we will confirm the datasheet curve for this exact set before you order.

The M in the code specifies a manual drain bowl. It suits machines that are attended regularly, and it also widens the regulator adjustment range to 0.05-0.9 MPa (7-130 psi), versus 0.15-0.9 MPa (20-130 psi) for the automatic and differential-pressure drain versions. Choose automatic drain if the installation runs unattended.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06MNWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC200C06MNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.