
The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06NWK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC family pairs a filter-regulator and a lubricator in one two-unit set: it strips water and particulate from compressed air, holds a set downstream pressure, and adds oil mist for the equipment fed from the outlet. This configuration is size 200 with PT1/8 ports, the fine 5 um (W) element, differential-pressure bowl draining, no pressure gauge (N) and a reverse/check valve (K) fitted after the regulator. Maximum inlet pressure is 1.0 MPa (145 psi); with differential-pressure draining the regulation range is 0.15-0.9 MPa (20-130 psi); the set runs from -5 to 70 C, non-freezing. At size 200 the bowls are PC (polycarbonate).
This is a genuine AirTAC part. The G series spans sizes 200 to 600 with ports from 1/8 in to 1 in, and each position of the code can be re-ordered: drain type (differential-pressure, automatic A or manual M), 5 um (W) or standard 40 um element, embedded square gauge or external round gauge in MPa, psi or bar scales, PT, G (BSPP) or NPT thread, and bracket option. Flow is published as curves, not a single rating, so we confirm the datasheet and sizing for your application on request.
| Model | Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C06NWK |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
A bench assembly fixture with small pneumatic clamp cylinders: the 1/8 in port suits compact clamp circuits, the 5 um element protects metering and control valves, and the check valve holds the regulator setting during supply dips.
Small sample-handling and dispense actuators on a laboratory rig: filtered, regulated and lubricated air in one compact two-unit station, with the round of the code left blank so no gauge clutters a tight panel.
A row of air screwdrivers at a rework or kitting bench: the lubricator carries oil mist to the tool motors, the 5 um element keeps fine grit out of the drivers, and the check valve prevents setting drift on supply loss.
Within the G series, step up from size 200 (PT1/8 here) to 300, 400 or 600 when your circuit needs a larger port and more flow. Drain choice for the filter bowl is differential-pressure (the default, as here), automatic (A) or manual (M); note that the regulation range depends on drain type: 0.15-0.9 MPa with auto or differential draining, 0.05-0.9 MPa with manual. Filter grade is 40 um standard, 5 um with W. The K option fits a reverse/check valve after the regulator, and N deletes the pressure gauge entirely. Thread is PT as standard, with G (BSPP) and NPT orderable as catalogue options; J deletes the bracket.
Flow figures are published as curves, not a single rated number, so send us your line pressure and required flow and we will confirm sizing from the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
AirTAC publishes G-series flow as performance curves rather than one rated figure, so we do not quote a single l/min or SCFM number here. Tell us your line pressure and required flow and we will confirm the correct size from the datasheet on request.
N deletes the pressure gauge, W selects the 5 um filter element instead of the standard 40 um, and K fits a reverse/check valve that holds the downstream setting if upstream pressure is lost. The blank drain position means differential-pressure draining, which sets the regulation range at 0.15-0.9 MPa (20-130 psi).
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.