The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C08MC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC series is a two-unit set combining a filter-regulator with a separate lubricator, delivering clean air, stable pressure and oil-mist lubrication from one purchase. This 200-size set is ported PT1/4 (PT thread, 1/4 in.). The manual drain (M) empties the bowl by hand at routine checks, and the W code fits the 5 um filter element in place of the standard 40 um grade for finer particle removal. The C1 gauge is the external round type reading in MPa. Maximum working pressure is 1.0 MPa (145 psi), the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi) on this manual-drain version, and the set is rated for -5 to 70 C. The filter and lubricator bowls on the 200 size are polycarbonate.
This is a genuine AirTAC part. The G series is offered in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in., and with automatic, manual or differential-pressure drains, 40 or 5 um elements, round or square gauges in MPa, psi or bar scales, a reverse-valve option, and G (BSPP) or NPT threads besides the PT standard. AirTAC publishes flow for the series as curves rather than a single rated figure, so we confirm datasheet figures for your application on request.
| Model | Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C08MC1W |
|---|---|
| Series | GFC200 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC200 | G-series two-unit set, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC200 · See datasheet · 40 µm |
|---|---|
| One size up | GFC300 |
| Three-unit equivalent | GC200-C0 |
| Build order | Filter regulator first, lubricator last |
Supply small pneumatic clamps on an electronics assembly fixture; the 5 um element suits the fine valves and cylinders typical of these stations.
Condition air feeding carton-forming and tucking cylinders on a pharmaceutical cartoning line, where finer filtration supports reliable small-valve operation.
Feed detail air tools and small actuated jigs at a maintenance bench with filtered, regulated, lubricated air; the manual drain fits an end-of-shift bowl check.
The 200 size with its 1/4 in. port fits compact circuits; step to 300, 400 or 600 as port size and flow demands grow. This set carries the manual drain (M); choose the automatic (A) or differential-pressure drain where condensate should leave unattended. The W code selects the 5 um element - keep it where finer filtration matters, or specify the standard 40 um where coarse protection is enough. The gauge is the external round type on an MPa scale, with psi (2) and bar (3) scales available. Thread is PT as standard, and G (BSPP) or NPT versions can be ordered. Because flow is published as curves rather than a single rating, ask us to confirm sizing for your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.
AirTAC publishes flow for the G series as curves rather than a single rated figure, so we do not state one number here. Tell us your circuit and duty, and we will confirm the sizing against the datasheet on request before you order.
The W code selects the 5 um element for circuits with fine valves, small cylinders or precision tools where finer particle removal helps; the standard 40 um grade covers general-purpose protection. Both grades are catalogue options on the GFC filter-regulator, so the choice is made in the code when you order.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.