AirTAC GFC200 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C08NWK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C08NWK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$68.40 $73.79Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C08NWK

GFC200C08NWK is a two-piece AirTAC GFC air-preparation set for compressed air: a filter-regulator body plus a separate lubricator, so filtration, pressure regulation and oil-mist lubrication come from one order. This configuration is the size 200 frame with a 1/4 in PT port, the 5 um filter element, the default differential-pressure drain, no pressure gauge, and a reverse (check) valve fitted. The regulator adjusts from 0.15 to 0.9 MPa (20-130 psi), maximum working pressure is 1.0 MPa (145 psi), the working temperature range is -5 to 70 C non-freezing, and the 200-size filter bowl is PC (polycarbonate).

This is a genuine AirTAC part. The GFC family runs in size 200, 300, 400 and 600 frames with ports from 1/8 in to 1 in, and options covering 40 um or 5 um elements, differential-pressure, automatic or manual drains, external round or square gauges in MPa, psi or bar scales, and a reverse/check valve. Flow for the G series is published as curves rather than a single rated figure, so we confirm the datasheet numbers for your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C08NWK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C08NWK
SeriesGFC200 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C08NWK

GFC200G-series two-unit set, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR200-C0 filter regulator and GL200-C0 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC200 · See datasheet · 40 µm
One size upGFC300
Three-unit equivalentGC200-C0
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C08NWK Is Used

precision_manufacturing

Pneumatic clamping on CNC fixtures

Feeds the clamp cylinders on a machining-centre fixture: the 5 um element cleans the air reaching the clamping valves, the regulator holds the clamp pressure you set, the lubricator mists oil for the cylinder seals, and the check valve guards against backflow.

handyman

Air-tool supply at a workshop bench

A point-of-use set for impact wrenches and air ratchets at a vehicle repair bench: filter, regulated pressure and oil mist in one two-piece set sized at 1/4 in PT, specified without a gauge where the bench panel already carries one.

settings_input_component

Pick-and-place gripper air on assembly cells

Conditions the supply to gripper and small-slide actuators on an electronics assembly cell, where the finer 5 um grade suits sensitive pneumatic components and the compact 200 frame fits crowded manifolds.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C08NWK the Right Set?

The real choices here: the 200 frame with a 1/4 in PT port is the compact step in the range (200/300/400/600) - match frame and port against the air your circuit actually uses. The W selects the 5 um element over the 40 um standard, N deletes the pressure gauge (external round or square gauges in MPa, psi or bar scales are orderable options), and K fits the reverse/check valve. Drain on this code is the default differential-pressure type; A (automatic) and M (manual) are the alternatives. PT is the standard thread, with G (BSPP) and NPT as catalogue options. G-series flow is published as curves rather than one rated number, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR200-C0 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C08NWK FAQ

AirTAC publishes G-series flow capacity as curves rather than a single rated figure, so we do not quote a number on the page. Tell us your working pressure and the air your circuit needs, and we will confirm the sizing from the datasheet on request.

No. N means no gauge is fitted on this set. GFC sets can be ordered with an external round gauge (C) or square gauge (F) in MPa (1), psi (2) or bar (3) scales - for example C1 for a round MPa gauge - so tell us if you want a gauge specified instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC200C08NWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC200C08NWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.