verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008ANWK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008ANWK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a automatic drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainAutomatic drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$83.39 $89.15Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008ANWK

The GFC30008ANWK combines every option on this size 300 two-unit set: a filter-regulator with automatic drain and the finer 5 um element, a matched lubricator, and a reverse-flow (check) valve designated by the trailing K. Ports are PT1/4 and no gauge is fitted. Downstream cylinders and tools receive filtered, regulated and lubricated air; maximum working pressure is 1.0 MPa (145 psi), the regulator adjustment range with automatic drain is 0.15-0.9 MPa (20-130 psi), and the temperature range is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. G-series two-unit sets are available in sizes 200 through 600 with your choice of drain type, 40 um or 5 um filtration, embedded square or external round gauges in MPa, psi or bar scale, the check-valve option, and G (BSPP) or NPT threads alongside the PT standard. Flow is published as curves rather than a single rating, so we confirm sizing and datasheet figures on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008ANWK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008ANWK
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeAutomatic drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008ANWK

GFC300G-series two-unit set, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
ADrain: Automatic drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/4" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-08
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008ANWK Is Used

precision_manufacturing

Palletizer gripper circuits

Conditioning air for vacuum-assist and gripper cylinders on a palletizer cell, with the 5 um element protecting the pilot valves and the check valve fitted as specified.

build

Mobile maintenance-truck air outlets

A filtered, regulated, lubricated outlet on a field-service truck feeding impact wrenches and drills, where the 5 um element suits the compact tool valves.

air

Air-actuated gate valves on process skids

Supplying conditioned air to cylinder-actuated gate and diverter valves on a process skid, with regulated pressure and oil mist for the actuator seals and linkage.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008ANWK the Right Set?

This code bundles the finer 5 um element (W) with the factory-fitted reverse-flow check valve (K) on the 300 size, 1/4 in port set - the natural pick when both finer filtration and the check valve are wanted without assembling options separately. The automatic drain keeps condensate off your maintenance schedule; manual and differential-pressure drains are alternatives. No gauge is included, but square or round gauges with MPa, psi or bar scales can be ordered. PT thread is standard, with G (BSPP) and NPT as catalogue alternatives. Because flow appears as curves rather than one rated figure, ask us to confirm sizing against the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008ANWK FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so no single number is quoted here. Send your line pressure, demand and duty cycle and we will confirm the correct size against the datasheet on request.

W specifies the finer 5 um filter element instead of the standard 40 um, and K specifies that a reverse-flow (check) valve is fitted. Both are catalogue options on the GFC two-unit sets and can be ordered individually or together.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008ANWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30008ANWK and will confirm price, stock and lead time — usually within 7-8 hours.