verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MC2W

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MC2W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$85.41 $91.21Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MC2W

The AirTAC GFC series is a two-unit air preparation set: a filter-regulator plus a lubricator, covering filtration, pressure regulation and oil-mist lubrication in one order. This GFC30008MC2W is the size 300 set with PT1/4 ports, a manual drain on the filter-regulator bowl, the fine 5 um filter element (W suffix), and an external round gauge reading in psi (the 2 scale code) - convenient where US plant gauges are read in psi. Maximum working pressure is 1.0 MPa (145 psi); with this manual-drain configuration the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi); operating temperature is -5 to 70 C (non-freezing). The bowls on this size 300 set are polycarbonate (PC).

This is a genuine AirTAC part for the US market. The GFC family is offered in sizes 200, 300, 400 and 600 with ports from 1/8 in. to 1 in., configured with your choice of drain type, 40 um or 5 um filtration, gauge scale (MPa, psi or bar), reverse valve, and G (BSPP) or NPT threads in place of the PT standard. Flow for the G series is published as curves rather than a single rated figure, so ask us and we will confirm the datasheet flow data for your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MC2W Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MC2W
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, psi scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MC2W

GFC300G-series two-unit set, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
2Gauge scale: psi. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/4" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-08
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MC2W Is Used

conveyor_belt

Bottling line grip cylinders

Supplying the grip and transfer cylinders on a bottling conveyor, the set filters plant air to 5 um, holds the pressure the grippers were tuned to, and lubricates the cylinder seals - with the psi gauge matching the readings on the rest of the US-built line.

valve

Process valve actuation skid

On a skid of quarter-turn pneumatic actuators, the unit cleans and regulates supply air to the actuators' set pressure, the psi gauge gives operators a familiar reading at the panel, and lubrication keeps the actuator seals serviced between maintenance windows.

handyman

Maintenance shop air drop

At a plant maintenance shop's tool drop, the two-unit set delivers clean, regulated, lubricated air to impact wrenches and air ratchets, with the 5 um element protecting tool governors and the psi gauge letting techs set pressure at a glance.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MC2W the Right Set?

Size 300 with 1/4 in. PT ports is the middle step of the G series; pick the size and port from your air demand and step up to size 400 (1/2 in. ports) if your flow nears the top of the size 300 curves. The 2 in this code selects a psi gauge scale - match the scale to how your technicians read pressure, with MPa and bar scales also available. The W element filters to 5 um for finer downstream protection; the 40 um standard is the choice for general plant air. The manual drain suits attended installations; order the automatic-drain code for unattended duty. Threads are PT as standard; specify G (BSPP) or NPT to match your piping. Flow is published as curves, not one rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MC2W FAQ

AirTAC publishes G-series flow as performance curves rather than a single rated figure, so no rated flow is stated here. Share your required flow and working pressure and we will confirm the datasheet curves for this 1/4 in., 5 um set with psi gauge on request.

The digit after the drain and gauge letters sets the scale: 1 is MPa, 2 is psi and 3 is bar. This model carries the 2 code, so its external round gauge reads in psi - a direct match for US plant practice. If your documentation is metric, order the MPa (1) or bar (3) version of the same set instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MC2W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30008MC2W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.