AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MLC1W

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MLC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a manual drain and regulation over 0.05 - 0.9 MPa (7 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$85.41 $91.21Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MLC1W

The AirTAC GFC series is a two-piece air-treatment set: a filter regulator plus a separate lubricator, so the air is filtered, regulated and then oil-mist lubricated in one supply line. This GFC30008MLC1W is the 300 size with 1/4 in PT ports, a manual drain on the filter bowl, a 5 um (W) filter element for finer particulate removal, the low-pressure regulator type, and an external round pressure gauge reading in MPa.

This is a genuine AirTAC part. The G series is offered in 200, 300, 400 and 600 sizes with a choice of PT, G(BSPP) or NPT threads, drain types, 40 um standard or 5 um filter grades, and square or round gauges. Flow is published as curves rather than a single rating, so we confirm the datasheet and sizing figures for your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MLC1W Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MLC1W
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MLC1W

GFC300G-series two-unit set, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/4" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-08
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MLC1W Is Used

precision_manufacturing

Pneumatic press tooling

Feeding filtered, regulated and lubricated air to the clamping and punching cylinders of a small pneumatic press, with the 5 um element guarding directional valves against fine contamination.

conveyor_belt

Packaging conveyor actuators

Supplying oil-mist lubricated air to the pusher and diverting cylinders along a packaging conveyor, where the low-pressure regulator type keeps actuation pressure gentle on lightweight product.

air

Air-assisted spray rig

Preparing the air feed to a spray-gun manifold, combining fine 5 um filtration, stable low-pressure regulation and in-line lubrication for the gun trigger valves.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MLC1W the Right Set?

The 300 size with 1/4 in PT ports is the entry point of the mid range; step up to 400 or 600 if your line needs larger ports and more flow, or down to 200 for compact circuits. The manual drain here suits installations where an operator bleeds the bowl as part of routine checks; choose the automatic drain variant for unattended duty. The 5 um element protects finer components than the 40 um standard, at the cost of more frequent element checks. The round MPa gauge is the external option; a square embedded gauge is also available in MPa, psi or bar scales.

Flow for this set is published as curves, not a single rated figure, so ask us to confirm sizing against your flow demand before ordering. PT is the standard thread; G(BSPP) and NPT are catalogue options to specify at order time.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MLC1W FAQ

AirTAC publishes flow for the GFC300 as performance curves rather than a single rated figure, so there is no one number we can honestly quote. Tell us your flow demand and we will confirm the sizing against the datasheet curves on request before you order.

The M in the code selects a manual drain, so the filter bowl is bled by hand during scheduled checks instead of automatically. The W selects the 5 um element instead of the 40 um standard, for finer protection of downstream components. The F.R.L. also uses the low-pressure regulator type and carries a round external gauge reading in MPa.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008MLC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30008MLC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.