verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008NW

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008NW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/4" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeNot fitted
  • ThreadPT
$61.60 $66.81Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008NW

The AirTAC GFC two-unit set pairs a filter-regulator with a lubricator, giving filtration, pressure regulation and oil-mist lubrication in one assembly. This GFC30008NW is built for 1/4 in. PT ports, uses the differential-pressure drain that bleeds condensate as air flows through, a 5 um fine filter element in place of the standard 40 um grade, and no gauge. With differential-pressure drainage the regulator adjusts from 0.15 to 0.9 MPa (20-130 psi).

It is a genuine AirTAC part, rated for compressed air at up to 1.0 MPa (145 psi) inlet and -5 to 70 C, non-freezing, with polycarbonate bowls at this 300 size. The GFC series spans sizes 200 to 600 with drain-type choices, gauge variants, a reverse-valve option and G (BSPP) or NPT threads. Flow is published as curves rather than a single rating, so we confirm flow and datasheet figures on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008NW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008NW
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeNot fitted
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008NW

GFC300G-series two-unit set, 300 body — sets the port range.
08Port size PT1/4". This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
NNo pressure gauge (N).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-08 filter regulator and GL300-08 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · PT1/4" · 5 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-08
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008NW Is Used

science

Analytical instrument air supply

Conditioning instrument air for lab analyzers and sample-handling panels, where the 5 um element gives finer filtration than the standard 40 um grade ahead of sensitive pneumatic components.

view_module

PCB pick-and-place air feed

Supplying the pneumatic feed of a PCB pick-and-place machine, with filtered, regulated and lubricated air serving the placement-head cylinders and the differential-pressure drain clearing condensate automatically.

speed

High-speed labelling head feed

Feeding the short-stroke cylinders on a labelling machine's application head, where the regulator sets the head pressure and the lubricator mists oil for the cylinders on each stroke.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008NW the Right Set?

Choose the size step (200, 300, 400 or 600) against the port and air demand of the line; this set is size 300 with 1/4 in. PT ports. Drain options are differential-pressure (this set, the default), automatic (A) or manual (M); the W in this code selects the 5 um filter element against the 40 um standard, for finer particulate removal ahead of sensitive components. Gauge variants add an embedded square or external round gauge on MPa, psi or bar scales. Thread is PT as standard, with G (BSPP) and NPT catalogue options. Because flow is published as curves rather than one rated figure, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-08 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008NW FAQ

Flow for the GFC300 is published as curves in the AirTAC datasheet, not as a single rated figure, so we do not state a number on the page. Send us your line pressure and air demand and we will confirm the curve and sizing from the datasheet on request before you order.

W changes the filter element from the standard 40 um grade to 5 um, for finer particulate removal ahead of sensitive devices such as precision valves, cylinders with close-tolerance seals or instrumentation. If your air feeds general plant equipment, the standard 40 um GFC30008N keeps the choice simpler and remains a catalogue variant of the same set.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC30008NW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC30008NW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.