verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08ANWK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08ANWK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$94.74 $100.78Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08ANWK

The AirTAC GFC is a two-unit air preparation set: a filter regulator and a lubricator combined so that air is filtered, regulated and oiled in one assembly. This GFC300C08ANWK is the 300 size with PT1/4 ports, a fine 5 um filter element and an automatic drain that ejects condensate without manual attention. The standard regulator adjusts across 0.15-0.9 MPa (20-130 psi) in this auto-drain configuration, and the trailing K means a reverse (check) valve is fitted, holding downstream pressure if the supply side is vented. No gauge is included in this variant.

This is a genuine AirTAC part. The G series spans 200 to 600 sizes with PT threads as standard and G (BSPP) or NPT as catalogue options, a choice of differential-pressure, automatic or manual drains, and 40 um or 5 um elements. Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08ANWK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08ANWK
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08ANWK

GFC300G-series two-unit set, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C0 filter regulator and GL300-C0 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C0
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08ANWK Is Used

build

Pneumatic press with safety hold

Conditions air for a small pneumatic press where the fitted check valve holds the regulated downstream side if the shop supply is shut off, while the 5 um element and auto drain keep the control valves clean and dry.

settings_input_component

Robot gripper control cabinets

Feeds the valve manifold and suction cups of a robotic pick-and-place cell, combining fine filtration, stable regulated pressure and lubrication, with the check valve protecting the circuit during supply interruptions.

science

Lab automation sample handlers

Prepares air for automated pipetting and sample-transfer modules in a laboratory line, where the 5 um grade guards precision components and the automatic drain suits equipment that runs without daily checks.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08ANWK the Right Set?

This code suits circuits where you want the 300 size at 1/4 in ports plus the check-valve benefit: the reverse valve prevents backflow from the downstream side, useful where a vented or dropped supply must not reverse through the set. The 5 um element with automatic drain is the low-maintenance combination for sensitive valves and unattended cells; choose the standard 40 um element only where downstream cleanliness demands are modest.

Specify PT (standard) unless your pipework needs G (BSPP) or NPT, both orderable options. As flow figures for the 300 size exist only as catalogue curves, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C0 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08ANWK FAQ

There is no single rated flow number to quote: AirTAC publishes the G series flow data as performance curves. Ask us for the datasheet and we will read the 300-size curve at your inlet pressure and confirm it against your application before you order.

The K code means a reverse (check) valve is fitted in the unit, so air cannot flow backwards from the regulated side toward the supply. The function set otherwise matches GFC300C08ANW: 1/4 in PT ports, 5 um element, automatic drain, standard regulator without gauge, plus the lubricator unit.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08ANWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC300C08ANWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.