verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08C1W

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08C1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$96.76 $102.84Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08C1W

The GFC series is AirTAC's two-unit air-treatment set: a filter regulator paired with a lubricator, giving filtration, pressure regulation and oil-mist lubrication from one orderable set. This GFC300C08C1W is the size 300 body on a PT1/4 port. The filter bowl uses the differential-pressure drain (the default) and is fitted with the 5 um W-grade element instead of the standard 40 um element, while the regulator carries a round pressure gauge with MPa scale and adjusts between 0.15-0.9 MPa (20-130 psi). It is for compressed air only, rated to 1.0 MPa (145 psi) inlet and -5 to 70 C.

This is a genuine AirTAC part. The G series is available in sizes 200, 300, 400 and 600 with ports from 1/8 inch to 1 inch, and the drain type, filter grade, gauge style and scale, and thread form (PT as standard, with G and NPT as catalogue options) are all selectable. Because AirTAC publishes flow as characteristic curves rather than a single rated figure, we confirm flow and other datasheet numbers on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08C1W Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08C1W
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08C1W

GFC300G-series two-unit set, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C0 filter regulator and GL300-C0 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C0
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08C1W Is Used

build

Paint spray booths

Feeding spray guns in an automotive refinish booth: the set filters and regulates the 1/4 inch air branch and meters oil mist to the gun's air valve and needle pack, with the 5 um element suiting finish-sensitive work.

precision_manufacturing

CNC clamping circuits

Supplying pneumatic clamping fixtures on a machining centre: the regulator holds a steady fixture pressure on the gauge while the lubricator feeds the swing clamps and chuck actuator.

view_module

Carton sealing lines

Air treatment for the tape heads and pusher cylinders on a packaging line's carton sealer: one two-unit set cleans, regulates and lubricates the whole 1/4 inch drop.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08C1W the Right Set?

Size 300 on a PT1/4 port suits branches where 1/4 inch piping feeds the downstream cylinders, valves and tools; if your demand outgrows it, the same set is offered in size 400 or 600 on larger ports. Choose the 5 um W element when the downstream equipment is sensitive to finer particulate than the standard 40 um element removes.

Drain here is the differential-pressure default, with automatic or manual drain available as options - note that a manual-drain version widens the regulator's lower adjustment limit to 0.05 MPa. The regulator range on this set is 0.15-0.9 MPa (20-130 psi), read on the round MPa gauge; a square gauge with MPa, psi or bar scale can be ordered instead. Thread is PT as standard, with G (BSPP) and NPT as orderable options. Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C0 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08C1W FAQ

AirTAC publishes flow for the G series as characteristic curves rather than a single rated figure, so we do not quote one number here. Send us your line pressure, downstream consumption and allowable pressure drop, and we will confirm the correct size and the curve data from the datasheet on request.

GFC is a two-unit set: a filter regulator plus a lubricator, so filtration, regulation and lubrication come in two pieces. GC is the three-unit F.R.L. combination, with a separate filter, regulator and lubricator. Functionally both cover filter + regulate + lubricate; the choice is about layout and mounting space in your plant.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08C1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC300C08C1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.