verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08NW

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08NW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$72.94 $78.44Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08NW

The AirTAC GFC series is a two-piece air preparation set: a filter regulator plus a lubricator ordered as one unit. This 300-size configuration is threaded PT1/4 and delivers three jobs at the station drop - the filter element removes water and particulate down to 5 um, the regulator holds a set working pressure across an adjustment range of 0.15-0.9 MPa (20-130 psi), and the lubricator adds an oil mist for downstream air tools and cylinders. The filter regulator uses a differential-pressure drain, and this version is supplied without a gauge.

This is a genuine AirTAC part. The G series runs from size 200 to size 600, with PT as the standard thread and G(BSPP) or NPT available as catalogue options, and the regulator can be ordered with an embedded square gauge or an external round gauge in MPa, psi or bar scale. Flow is published as curves rather than a single rated figure, so we confirm datasheet and sizing numbers on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08NW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08NW
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08NW

GFC300G-series two-unit set, 300 body — sets the port range.
C0Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C0 filter regulator and GL300-C0 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C0
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08NW Is Used

precision_manufacturing

Pneumatic punch press feed

A two-unit set on the supply drop to a small pneumatic press: the 5 um element protects the directional valve, the regulator holds the working pressure for the forming stroke, and the lubricator keeps the press cylinders running on oiled air.

build

Assembly bench air tools

Feeding impact drivers and nut runners at an assembly station, where the lubricator carries an oil mist to the vane motors and the 5 um filtration keeps grit out of the tool governors and couplings.

conveyor_belt

Packaging conveyor actuators

Supplying the stopper gates and pusher cylinders along a packaging conveyor line, with filtered, regulated and lubricated air at each 1/4 in station drop off the main header.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08NW the Right Set?

The practical choices in this family are size and port, filter grade, drain type, gauge and thread. Size 300 at PT1/4 is the mid step of four sizes (200/300/400/600); step up if your line's flow demand sits above what a 1/4 in drop can carry, since published flow is a curve, not one number. The 5 um (W) element suits valves and tools that need finer air than the 40 um standard; the differential-pressure drain is the default and needs no setting, while automatic (A) and manual (M) drains are orderable alternatives. Thread is PT here, with G and NPT as orderable options.

Because flow is published as curves rather than a single rating, send us your application's flow and pressure points and we will confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C0 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08NW FAQ

AirTAC publishes flow for the G series as curves rather than a single rated figure, so we do not quote one number here. Tell us your required flow and working pressure and we will confirm the sizing against the datasheet on request.

This set carries the W-grade 5 um element instead of the 40 um standard, which is the better match for directional valves and air tools that suffer from finer contamination. The differential-pressure drain is the default option: it purges collected condensate automatically as air flows through the bowl, with no operator setting needed.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C08NW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC300C08NW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.