The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10ANW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$83.39 $89.15Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10ANW

GFC300C10ANW is an AirTAC G-series two-unit set: a filter regulator and a separate lubricator supplied as one pair. The filter stage removes water and particulate through a 5 um element, and the automatic drain discharges condensate from the bowl without operator attention, which suits lines that run unattended. The regulator holds downstream pressure in the 0.15-0.9 MPa (20-130 psi) range, and the lubricator meters oil mist into the air stream for downstream cylinders, valves and tools. Ports are PT 3/8 in, and this code is ordered without a gauge.

This is a genuine AirTAC part. The G series is offered in sizes 200, 300, 400 and 600 with ports from 1/8 to 1 in, plus drain, filter-grade, gauge, thread (PT as standard, with G/BSPP and NPT as catalogue options) and bracket choices, so a matching unit can be configured for most lines. Flow is published as curves rather than a single rating; ask us and we will confirm the datasheet figures for your application.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10ANW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10ANW
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10ANW

GFC300G-series two-unit set, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C1
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10ANW Is Used

precision_manufacturing

Robotic weld-cell actuators

Feeding filtered, regulated and lubricated air to pick-and-place cylinders on a robotic weld cell, where the 5 um element protects valve spools and the automatic drain keeps the bowl clear across multi-shift runs.

factory

Bottling line air motors

Supplying the vane air motors that drive conveyors and agitators on a bottling line: oil mist keeps the motors running smoothly while the regulator holds a steady working pressure at the machine.

build

Assembly bench impact tools

Point-of-use supply for impact wrenches and nutrunners at an assembly bench, with the 5 um element guarding the tools and downstream pressure set anywhere between 0.15 and 0.9 MPa.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10ANW the Right Set?

Choose the size by port and demand: this 300 set carries 3/8 in PT ports, the mid step of the range; step down to 200 or up to 400/600 as the line requires. This code fixes the day-to-day choices: a 5 um element for finer filtration than the standard 40 um, an automatic drain for unattended condensate removal, and no gauge. If you want a pressure readout, the same set is available with a square or round gauge in MPa, psi or bar scale. Thread is PT as standard; G (BSPP) and NPT are orderable options, and the differential-pressure and manual-drain variants are listed separately. Flow is published as curves, not a single rated figure, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10ANW FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so there is no one number we can honestly quote. Tell us your line pressure and air demand and we will confirm the flow from the datasheet on request before you order.

The N in the code means the set is supplied without a gauge. The same 300-size two-unit set can be ordered with a square or round gauge in MPa, psi or bar scale; choose that variant at order time if you want a visible pressure readout.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10ANW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC300C10ANW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.