The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10C1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC300C10C1W is a two-unit F.R.L. set: a GFR300 filter-regulator paired with a GL300 lubricator, so filtration, pressure regulation and oil-mist lubrication are covered by one order on a 3/8 in PT port. This configuration carries the finer 5 um filter element, a differential-pressure drain on the bowl, an external round pressure gauge scaled in MPa, and standard regulation with an adjust range of 0.15-0.9 MPa (20-130 psi). Both bowls on this size 300 set are polycarbonate.
This is a genuine AirTAC part. Maximum inlet pressure is 1.0 MPa (145 psi) and the working temperature range is -5 to 70 C (non-freezing). The G series is also available in sizes 200, 300, 400 and 600 with manual or automatic drains, G (BSPP) or NPT threads, psi or bar gauge scales, and a reverse/check valve option. Flow is published as curves rather than a single rated figure, so ask us to confirm flow and datasheet details for your application.
| Model | Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10C1W |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · See datasheet · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-C1 |
| Build order | Filter regulator first, lubricator last |
Feed filtered, regulated and lubricated air to the tool-changer and clamping cylinders of a machining center; the 5 um element helps keep fine pilot valves clean.
Supply a stable, regulated and oiled air signal to solenoid-piloted diaphragm valves on a water-treatment or dosing skid.
Run the pop-up diverter cylinders on a parcel-sort conveyor from one set that filters, regulates and lubricates the plant air at the drop.
Size 300 with a 3/8 in PT port sits mid-range in the G series: step up to 400 or 600 for larger ports and more flow, or down to 200 for compact drops. The 5 um element (code W) is the finer of the two grades and suits pilot valves and precision actuators; the standard grade is 40 um. Drain options are differential-pressure (as decoded here), automatic, or manual, and the regulator adjust range differs by drain type. Gauge scale can be ordered in MPa, psi or bar, the thread can be specified as G (BSPP) or NPT instead of the PT standard, and a reverse/check valve is available. Because flow is published as curves, not a single rating, ask us to confirm sizing against your application before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.
AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow data from the datasheet so you can size the 3/8 in port correctly before ordering.
This unit carries the 5 um grade (code W), the finer of the two filter options in the G series. It is the usual choice ahead of pilot valves, precision actuators and instruments; the standard 40 um grade is the default for general plant air. Both grades are available across the GFC range if your other drops differ.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.