verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNW

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$72.94 $78.44Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNW

The AirTAC GFC two-unit set pairs a filter-regulator with a lubricator, delivering filtered, regulated and oil-mist lubricated compressed air from one matched pair. This GFC300C10MNW is the 300 size with 3/8 in ports on PT thread (PT is the standard; G and NPT are catalogue options). The bowl drains manually, the element is the finer 5 um W grade, and the N option means no pressure gauge is fitted. Maximum inlet pressure is 1.0 MPa (145 psi); on this manual-drain version the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi). Working temperature is -5 to 70 C, non-freezing, and the filter bowl at this size is PC (polycarbonate).

This is a genuine AirTAC part. The G series comes in 200, 300, 400 and 600 sizes with stepped ports, and options include the 40 um standard element, automatic or differential-pressure drains, gauges with MPa, psi or bar scales, G (BSPP) or NPT threads, brackets and the check-valve option. Flow is published as curves rather than a single rated figure, so ask us to confirm sizing and request the datasheet for this exact code.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNW
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNW

GFC300G-series two-unit set, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C1
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNW Is Used

local_shipping

Trailer-door actuators at a loading dock

Conditions the air feeding dock door cylinders: water and fine particles removed, opening pressure set at the regulator, and oil mist carried to the cylinder seals.

valve

Actuated ball valves on a process skid

Supplies quarter-turn pneumatic actuators with clean, regulated, lubricated air, with the 5 um element guarding the solenoid and pilot valves on the skid.

handyman

Air screwdriver stations on a bench line

Feeds a row of pistol-grip screwdrivers from one set: filtered and regulated supply with oil mist for the tool motors, and no gauge where panel instruments already read pressure.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNW the Right Set?

The 300 size with PT3/8 ports is the middle step of the range - move to 200 or 400 if your line's flow band and port differ; each size changes both. Manual drain (M) fits a station an operator already services; automatic (A) and differential-pressure (blank) drain codes suit unattended points. The W element's 5 um grade is chosen here for finer filtration; the 40 um standard is the non-W default. The N option omits the gauge - add a gauge code (square or round, MPa, psi or bar scale) if you want set pressure visible at the unit. PT is the standard thread; order G (BSPP) or NPT where your piping needs it. Flow is published only as curves, so ask us to confirm this size against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNW FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so no capacity number is stated here. Tell us the machine and duty and we will confirm this 300 size, PT3/8 code against the datasheet on request.

Yes. Gauge-fitted codes carry the embedded square gauge, and a round external gauge is the alternative, with MPa (1), psi (2) or bar (3) scales. Choose a code such as GFC300C10MF1W to get the square MPa gauge on the same 300 size, PT3/8 set.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC300C10MNW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.