verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNWK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNWK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$84.30 $90.07Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNWK

The AirTAC GFC series is a two-unit set: a filter-regulator and a separate lubricator in one ordered package, giving filtration, pressure regulation and oil-mist lubrication from compressed air. This GFC300C10MNWK is size 300 with PT3/8 ports. The filter bowl uses a manual drain and a 5 um element (the W grade), so finer particle capture than the standard 40 um element. No gauge is fitted; the set also carries a reverse (check) valve, and the regulator adjustment range with manual drain is 0.05-0.9 MPa (7-130 psi). Maximum working pressure is 1.0 MPa (145 psi); working temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part. The GFC family is offered in sizes 200, 300, 400 and 600 with a choice of ports, drain types, filter grades and thread forms. Flow is published as curves rather than a single rated figure, so we confirm the datasheet and sizing against your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNWK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNWK
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNWK

GFC300G-series two-unit set, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C1
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNWK Is Used

tune

Paint booth gun air prep

Filters and regulates the air feeding spray guns on a finishing line, while the lubricator mists oil to keep gun trigger and air-motor internals running smoothly; the 5 um element helps protect finish quality.

settings_input_component

Robot gripper pneumatic panel

A two-unit set mounted on a pick-and-place robot's valve manifold panel, cleaning and stabilizing supply air and lubricating the gripper cylinders served by PT3/8 drop lines.

conveyor_belt

Packaging conveyor actuators

Feeds the pushers and stop cylinders along a carton packaging conveyor, with the check valve helping hold downstream pressure if the main supply dips.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNWK the Right Set?

Step up or down between sizes 200/300/400/600 to match the port and flow of the line; this unit is size 300 on PT3/8. Manual drain (M) suits points where an operator can bleed the bowl regularly, and it widens the regulator adjustment range to 0.05-0.9 MPa. The W grade gives 5 um filtration instead of the standard 40 um. Thread here is PT as standard; G (BSPP) and NPT are catalogue options. A bracket is included by default. Since flow is published only as curves, ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNWK FAQ

AirTAC publishes flow for the G series as curves, not as a single rated number, so we do not quote a figure here. Send us your application details and we will confirm the datasheet curve and correct sizing for the GFC300C10MNWK on request.

The M code means the filter bowl is drained by hand at service intervals, which suits attended installations and widens the regulator adjustment range to 0.05-0.9 MPa (7-130 psi). If nobody can drain the bowl regularly, choose an automatic (A) or differential-pressure (blank) drained version instead.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C10MNWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC300C10MNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.