verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANW

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$83.39 $89.15Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANW

The AirTAC GFC300C15ANW is a two-unit air-treatment set: a filter regulator plus a lubricator, covering filtration, pressure regulation and oil-mist lubrication together. This 300-size set carries PT1/2 ports (PT is the standard thread; G and NPT are catalogue options), an automatic drain on the bowl, and the fine 5 um (W) filtering element. No gauge is fitted and no reverse valve is included in this code.

This is a genuine AirTAC part. The GFC family is offered in 200, 300, 400 and 600 sizes with 40 um standard or 5 um fine elements, differential-pressure, automatic or manual drains, and optional square or round gauges in MPa, psi or bar scales. Maximum working pressure is 1.0 MPa (145 psi); working temperature is -5 to 70 C, non-freezing. Flow is published as curves, not a single rated figure, so we confirm datasheet figures on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANW
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANW

GFC300G-series two-unit set, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C1
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANW Is Used

science

Laboratory pneumatic test bench

Supplies clean, regulated and lubricated air to a lab test bench running pneumatic fixtures, with the 5 um element suiting sensitive instrumentation downstream.

air

Textile machine air-jet circuit

Conditions air for the fine nozzles and guide cylinders of a textile machine, where the fine 5 um grade helps keep small orifice components working reliably.

valve

Process pilot-valve supply manifold

Feeds a manifold of pneumatic pilot valves on a process skid, combining regulation, fine filtration and lubrication in one two-unit set.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANW the Right Set?

Match the frame to your demand: 300 size gives 1/2" PT ports here, while 400 and 600 sizes increase port and flow capacity. With the automatic drain fitted, the regulator spans 0.15-0.9 MPa (20-130 psi); the manual-drain variant widens this to 0.05-0.9 MPa (7-130 psi). The 5 um element in this code is the right choice ahead of air bearings, pilot valves or measuring devices; choose the standard 40 um element for general cylinder air. Gauge (round or square, MPa/psi/bar) and the K reverse valve are order options.

Because G-series flow appears only as curves, ask us to check your pressure and flow against the datasheet before ordering. Specify thread G (BSPP) or T (NPT) at order time if PT does not match your pipework.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANW FAQ

Yes - on request. AirTAC publishes G-series flow as curves rather than a single rated figure, so this page quotes no number. Send us your line pressure and required flow and we will confirm the datasheet figures and check the sizing with you before you order.

The W suffix selects the 5 um fine filtration element instead of the standard 40 um one, which matters when the set feeds precision components. If your application only needs general particulate removal, the same set is available with the standard 40 um element - and drain type, gauge and check-valve options are also selectable in the code.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC300C15ANW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.