verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANWK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANWK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$94.74 $100.78Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANWK

The AirTAC GFC300C15ANWK is a two-unit air-treatment set made up of a filter regulator and a lubricator, so it filters, regulates and lubricates compressed air from a single order line. This 300-size configuration has PT1/2 ports (PT is the standard thread; G and NPT are catalogue options), an automatic drain on the bowl, the fine 5 um (W) filtering element, no gauge, and a reverse (check) valve fitted.

This is a genuine AirTAC part. The GFC series runs from 200 to 600 sizes, with 40 um standard or 5 um fine filtration, differential-pressure, automatic or manual drains, and optional square or round gauges in MPa, psi or bar scales. Maximum working pressure is 1.0 MPa (145 psi); working temperature is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANWK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANWK
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANWK

GFC300G-series two-unit set, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C1
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANWK Is Used

engineering

Robotic weld-cell clamp supply

Conditions air for the weld-gun clamps and positioner locks in a robotic weld cell, with the check valve helping hold clamp pressure during supply dips.

handyman

Maintenance shop air drop

Serves a plant maintenance drop feeding impact tools and pneumatic rigging, giving filtered, regulated and lubricated air at a 1/2" connection point.

speed

High-cycle pick-and-place station

Prepares air for the gripper cylinders of a high-cycle pick-and-place station, where the fine 5 um element and automatic drain reduce intervention between shifts.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANWK the Right Set?

Step the size and port to your air demand: this unit uses 1/2" PT ports in the 300 frame, and the 400 or 600 frames suit heavier circuits. The automatic drain keeps the bowl clear without operator input; with this drain type the regulator spans 0.15-0.9 MPa (20-130 psi), while the manual-drain option widens the span to 0.05-0.9 MPa (7-130 psi). The 5 um element protects fine components; the standard 40 um element serves general supply. The K suffix fits a reverse (check) valve here, and gauge options (round or square, MPa, psi or bar) can be selected in the code if you want a pressure reading at the unit.

Flow is published as curves, not a single rated number, so ask us to confirm sizing from the datasheet against your application before ordering. PT is the standard thread; order G (BSPP) or T (NPT) where your system requires them.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANWK FAQ

We do not quote a single rated-flow figure because AirTAC publishes G-series capacity as flow curves. Provide your working pressure and required flow and we will confirm the relevant datasheet figures and verify the sizing on request before you order.

A GFC set pairs a filter regulator with a lubricator in two pieces, covering filtration, regulation and lubrication with fewer components and connections. A GC combination uses three separate units - filter, regulator and lubricator - which suits layouts where the filter must sit far upstream or units are mounted individually. Both families share the same size, drain, grade, gauge and thread options.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC300C15ANWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.