The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANWK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GFC300C15ANWK is a two-unit air-treatment set made up of a filter regulator and a lubricator, so it filters, regulates and lubricates compressed air from a single order line. This 300-size configuration has PT1/2 ports (PT is the standard thread; G and NPT are catalogue options), an automatic drain on the bowl, the fine 5 um (W) filtering element, no gauge, and a reverse (check) valve fitted.
This is a genuine AirTAC part. The GFC series runs from 200 to 600 sizes, with 40 um standard or 5 um fine filtration, differential-pressure, automatic or manual drains, and optional square or round gauges in MPa, psi or bar scales. Maximum working pressure is 1.0 MPa (145 psi); working temperature is -5 to 70 C, non-freezing. Flow is published as curves rather than a single rating, so we confirm datasheet and sizing figures on request.
| Model | Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15ANWK |
|---|---|
| Series | GFC300 two-unit set |
| Composition | Filter regulator + lubricator (2 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GFC300 | G-series two-unit set, 300 body — sets the port range. |
|---|---|
| C1 | Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.
A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.
| This model | GFC300 · See datasheet · 40 µm |
|---|---|
| One size down | GFC200 |
| One size up | GFC400 |
| Three-unit equivalent | GC300-C1 |
| Build order | Filter regulator first, lubricator last |
Conditions air for the weld-gun clamps and positioner locks in a robotic weld cell, with the check valve helping hold clamp pressure during supply dips.
Serves a plant maintenance drop feeding impact tools and pneumatic rigging, giving filtered, regulated and lubricated air at a 1/2" connection point.
Prepares air for the gripper cylinders of a high-cycle pick-and-place station, where the fine 5 um element and automatic drain reduce intervention between shifts.
Step the size and port to your air demand: this unit uses 1/2" PT ports in the 300 frame, and the 400 or 600 frames suit heavier circuits. The automatic drain keeps the bowl clear without operator input; with this drain type the regulator spans 0.15-0.9 MPa (20-130 psi), while the manual-drain option widens the span to 0.05-0.9 MPa (7-130 psi). The 5 um element protects fine components; the standard 40 um element serves general supply. The K suffix fits a reverse (check) valve here, and gauge options (round or square, MPa, psi or bar) can be selected in the code if you want a pressure reading at the unit.
Flow is published as curves, not a single rated number, so ask us to confirm sizing from the datasheet against your application before ordering. PT is the standard thread; order G (BSPP) or T (NPT) where your system requires them.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.
We do not quote a single rated-flow figure because AirTAC publishes G-series capacity as flow curves. Provide your working pressure and required flow and we will confirm the relevant datasheet figures and verify the sizing on request before you order.
A GFC set pairs a filter regulator with a lubricator in two pieces, covering filtration, regulation and lubrication with fewer components and connections. A GC combination uses three separate units - filter, regulator and lubricator - which suits layouts where the filter must sit far upstream or units are mounted individually. Both families share the same size, drain, grade, gauge and thread options.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.