verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC300 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15NWK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15NWK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$84.30 $90.07Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15NWK

The AirTAC GFC series combines a filter regulator and a lubricator in one two-piece set, so filtration, pressure regulation and oil-mist lubrication come from a single order. This GFC300C15NWK is the size 300 unit with 1/2 in PT ports, the finer 5 um filter element and a differential-pressure drain on the filter bowl. It is supplied without a pressure gauge, and a reverse (check) valve is fitted to the regulator section, which adjusts outlet pressure across 0.15-0.9 MPa (20-130 psi). Both sections run on compressed air from -5 to 70 C (non-freezing) at up to 1.0 MPa (145 psi) inlet, with polycarbonate bowls.

This is a genuine AirTAC part. The G series spans sizes 200 to 600 with ports from 1/8 in to 1 in, G (BSPP) and NPT thread variants, manual and automatic drain options, 40 um and 5 um elements, and embedded square or external round gauges in MPa, psi or bar scales, so a close match can be ordered for most installations. Flow is published as curves rather than a single rating; ask us to confirm the datasheet figures and sizing for your application.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15NWK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15NWK
SeriesGFC300 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15NWK

GFC300G-series two-unit set, 300 body — sets the port range.
C1Port size See datasheet. This body offers 08 = PT1/4", 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR300-C1 filter regulator and GL300-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC300 · See datasheet · 40 µm
One size downGFC200
One size upGFC400
Three-unit equivalentGC300-C1
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15NWK Is Used

conveyor_belt

Carton sealing line

Feeds filtered, regulated and lubricated air to the cylinders and vacuum generators on a carton-sealing conveyor; the 5 um element keeps grit out of valve seals while the lubricator mists oil into the actuator air.

valve

Actuated valve manifold

Supplies clean, regulated air to quarter-turn actuators on a water-treatment valve manifold; the fitted check valve helps hold the regulated pressure if the plant air main dips.

engineering

CNC clamping cell

Powers power clamps and swing cylinders on a CNC machining cell, where the regulator holds fixture pressure and the lubricator keeps the clamp cylinders sealing over long production runs.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15NWK the Right Set?

Size 300 with 1/2 in PT ports is the mid step of the G series - step to size 400 or 600 for larger ports, or to size 200 for compact branches. Drain type here is the standard differential-pressure drain; manual (M) and automatic (A) drains can be ordered instead. The W in this code selects the finer 5 um element (40 um is standard), N removes the gauge - round or square gauges with MPa, psi or bar scales are order options - and K adds the reverse (check) valve. PT is the standard thread; G (BSPP) and NPT are catalogue options.

Flow is published as curves rather than a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR300-C1 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15NWK FAQ

AirTAC publishes G-series flow as curves rather than a single rated figure, so there is no one number to quote here. Tell us your line pressure and air consumption and we will confirm the sizing from the datasheet on request before you order.

The N in the code means no gauge is fitted. Gauge versions can be ordered instead: an embedded square gauge or an external round gauge, each with MPa, psi or bar scale options. Everything else in this 1/2 in, 5 um, check-valve configuration stays the same.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC300C15NWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC300C15NWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.