verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40015LC1W

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC40015LC1W is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with PT1/2" ports, a 5 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizePT1/2"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade5 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$118.55 $125.18Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40015LC1W

GFC40015LC1W is a genuine AirTAC G-series two-unit air-treatment set: a filter-regulator and a lubricator supplied as one matched pair, covering filtration, pressure regulation and oil-mist lubrication on a single order. This size 400 unit is threaded PT1/2 (1/2 in) and the W code selects the finer 5 um filter element instead of the 40 um standard, for cleaner air to sensitive downstream components. It has a differential-pressure drain, is built on the low-pressure (L) regulator type, and includes a round external pressure gauge on the MPa scale. Both bowls on this 400 size are PC (polycarbonate). Max working pressure is 1.0 MPa (145 psi) and operating temperature is -5 to 70 C (non-freezing); the medium is compressed air only.

This is a genuine AirTAC part sold through our US distribution. The GFC two-unit series spans sizes 200, 300, 400 and 600, with drain choices (differential-pressure, automatic or manual), 40 um standard or 5 um (W) filtration, gauge scales in MPa, psi or bar, and G (BSPP) or NPT thread options. AirTAC publishes flow for these units as curves rather than a single rated figure, so we confirm the flow and datasheet figures for your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40015LC1W Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40015LC1W
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizePT1/2" (PT thread)
Filtering grade5 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeLow-pressure type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — round, MPa scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. The low-pressure type adjusts over a lower band than standard; we confirm the exact figures from the factory datasheet. The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40015LC1W

GFC400G-series two-unit set, 400 body — sets the port range.
15Port size PT1/2". This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
LLow-pressure type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
1Gauge scale: MPa. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-15 filter regulator and GL400-15 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · PT1/2" · 5 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-15
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40015LC1W Is Used

science

Lab automation actuator supply

Feeds the pneumatic grippers and lift cylinders on laboratory automation benches, where the 5 um element keeps fine contamination away from precision valve internals and the lubricator protects high-cycle cylinders.

valve

Process skid control valve supply

Conditions instrument-quality air ahead of pneumatic positioners and control valves on a process skid, combining fine filtration with a held set point so the positioner receives steady, clean supply pressure.

conveyor_belt

Conveyor divert and stop stations

Placed at the supply to diverter gates, stops and pushers along a conveyor line, removing condensate and fine particles while holding regulated pressure for repeatable gate timing.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40015LC1W the Right Set?

Size 400 with PT1/2 ports suits larger machine supply lines in the G-series range; step to 300 or 600 as your port size dictates. The W code fits the 5 um element here - choose it over the 40 um standard when precision valves, air bearings or measuring equipment sit downstream. Drain options are the differential-pressure drain fitted here, automatic (A), or manual (M). Gauge choices are the round external MPa gauge fitted here, the embedded square gauge, psi or bar scales, or no gauge. This is the low-pressure (L) regulator type; its setting range is specific to that type and we confirm the exact figures on request. Thread is PT as standard, with G (BSPP) or NPT available to order. AirTAC publishes flow as curves rather than a single rating, so ask us to confirm sizing before ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/2" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-15 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40015LC1W FAQ

AirTAC publishes flow for the G series as capacity curves, not as a single rated figure, so we do not state one number here. Share your working pressure and demand and we will confirm the flow and datasheet figures for this unit on request.

Choose the W code when the downstream equipment is sensitive to fine particles - precision valves, positioners, measuring devices or high-cycle cylinders. GFC40015LC1W fits the 5 um element in the same PT1/2, size 400 low-pressure set with differential-pressure drain and MPa round gauge.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC40015LC1W

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC40015LC1W and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.