verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C10ANWK

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C10ANWK is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$132.42 $139.39Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C10ANWK

GFC400C10ANWK is an AirTAC G-series two-unit F.R.L. set: a 400-size filter-regulator plus a matching lubricator, delivering filtration, pressure regulation and oil-mist lubrication as one ordered item. It combines two code options: the W element, a finer 5 um filter in place of the 40 um standard, and the K reverse (check) valve, which retains downstream pressure if the upstream supply is interrupted. The automatic drain on the bowl expels condensate without manual attention and the regulator adjusts across 0.15-0.9 MPa (20-130 psi); no gauge is fitted. The port is 3/8 in. PT, the standard thread, with G (BSPP) and NPT versions available as catalogue options. The medium is compressed air only, maximum working pressure is 1.0 MPa (145 psi), the bowls are polycarbonate at this size, and the working temperature range is -5 to 70 C (non-freezing).

This is a genuine AirTAC part. The GFC two-unit concept is available in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 in., a choice of differential-pressure, automatic or manual drains, 40 um standard or 5 um (W) filtration, check-valve option (K), and gauge options. AirTAC publishes flow as characteristic curves rather than a single rated figure, so we confirm the datasheet and sizing figures for your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C10ANWK Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C10ANWK
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C10ANWK

GFC400G-series two-unit set, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-C1 filter regulator and GL400-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · See datasheet · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-C1
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C10ANWK Is Used

valve

Pilot-air supply to process valve positioners

Conditions pilot air to valve positioners on a process line, where the 5 um element protects the positioner's fine internals and the check valve holds the regulated pilot pressure if the header dips.

precision_manufacturing

Workholding on a vertical machining center

Supplies and holds air to precision workholding clamps on a vertical machining center, with the check valve retaining clamp pressure and the 5 um element suiting small pilot valves.

cable

Wire and cable winding machine pneumatics

Feeds the tensioning and guide cylinders of a wire winding machine, where sustained holding pressure between cycles and cleaner air for compact control valves keep the wind consistent.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C10ANWK the Right Set?

Step through the 200/300/400/600 sizes and their ports - this model is 400 size with a 3/8 in. PT port - to match the air consumption of the downstream circuit. This variant pairs the 5 um (W) filter element with the K reverse (check) valve for circuits that need both cleaner air and pressure retention on supply loss. The drain is automatic; manual and differential-pressure types are the other catalogue choices. A gauge - embedded square or external round, on MPa, psi or bar scales - can be added since none is fitted. PT is the standard thread; order G (BSPP) or NPT where the installation needs it. Flow is published as curves, not a single rating, so ask us to confirm sizing against the application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-C1 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C10ANWK FAQ

AirTAC publishes G-series flow as characteristic curves rather than a single rated figure, so we do not quote a number here. Ask us and we will confirm the flow and datasheet figures for this exact model against your application before you order.

With no thread letter, PT is the standard thread on this model, hence the 3/8 in. PT port. G (BSPP) and NPT versions are catalogue options to order - specify the thread you need and we will quote the matching AirTAC part.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C10ANWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC400C10ANWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.