verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GFC400 · Two-Unit Set (filter regulator + lubricator)

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C15NW

The AirTAC B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C15NW is a genuine G-series two-unit air-preparation set: a filter regulator that filters and regulates in one body, coupled to a lubricator. Two bodies do the work of three, with See datasheet ports, a 40 µm element, a differential-pressure drain and regulation over 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeTwo-unit set (F.R. + L.)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$110.63 $117.06Save 5% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C15NW

GFC400C15NW is a genuine AirTAC G-series two-unit set combining a filter-regulator and a lubricator in one order, providing filtration, pressure regulation and oil-mist lubrication of compressed air. This size 400 configuration is ported 1/2 in with PT thread as standard and specifies the 5 um filter element (code W) instead of the standard 40 um grade, making it the version to specify where finer air quality matters. The bowls use the default differential-pressure drain, the regulator adjusts from 0.15-0.9 MPa (20-130 psi), and no gauge or check valve is fitted. Maximum working pressure is 1.0 MPa (145 psi); operating temperature is -5 to 70 C.

The G-series two-unit family runs from sizes 200 through 600, with differential-pressure, automatic or manual draining, 40 um or 5 um filtration, gauge options, check-valve variants, and G (BSPP) or NPT threads as catalogue alternatives to the standard PT. Both bowls on this size are polycarbonate. Flow for the series is published as curves rather than a single rated figure, so we confirm datasheet and flow figures for your application on request.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C15NW Technical Specifications

ModelAirtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C15NW
SeriesGFC400 two-unit set
CompositionFilter regulator + lubricator (2 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The set has no separate bracket code — the two units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C15NW

GFC400G-series two-unit set, 400 body — sets the port range.
C1Port size See datasheet. This body offers 10 = PT3/8", 15 = PT1/2".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination set. Constituent units, orderable separately as spares: GFR400-C1 filter regulator and GL400-C1 lubricator.

Size Class & How It Differs From GC

  • GFC200PT1/8" - PT1/4"
  • GFC300PT1/4" - PT1/2"
  • GFC400PT3/8" - PT1/2"
  • GFC600PT3/4" - PT1"

A GFC is two units because filtering and regulating share one body. A GC is three separate units — filter, regulator and lubricator. Both filter, regulate and lubricate; the GFC is the shorter assembly, the GC keeps the filter and regulator serviceable as separate bodies.

This modelGFC400 · See datasheet · 40 µm
One size downGFC300
One size upGFC600
Three-unit equivalentGC400-C1
Build orderFilter regulator first, lubricator last

Where the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C15NW Is Used

science

Laboratory test rig

Supplies regulated air to pneumatic test benches and calibration rigs in a lab, where 5 um filtration protects precision components and the lubricator can be dosed only where moving parts need it.

air

Sensor air on an assembly line

Feeds pneumatic proximity sensors and air-gauge measuring points along an assembly line, where finer 5 um air helps keep small orifices clear and the regulator holds a stable measuring pressure.

speed

Air-motor drive on a bottling line

Prepares supply air for air-motor drives and rapid-cycling cylinders on a bottling line, with 5 um filtration guarding the motor vanes and the lubricator carrying the oil mist they rely on.

Is the Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C15NW the Right Set?

Here the deciding choice is the filter grade: the W in this code selects the 5 um element over the 40 um default, the right call when the same air feeds spraying equipment, air bearings, sensitive valves or instrumentation. Everything else is the standard configuration: size 400 with a 1/2 in PT port and differential-pressure drain, regulating 0.15-0.9 MPa (20-130 psi). If your demand needs a different port, step to GFC300 or GFC600; for a manual drain with a wider 0.05-0.9 MPa (7-130 psi) span, or a check valve, ask for those variants. No gauge is fitted, and G (BSPP) or NPT threads are catalogue options to order.

Flow is published as curves, not a single rating, so ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Two-unit (GFC) or three-unit (GC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter regulator first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the set above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream, so if any branch must stay oil-free, take that branch off before the lubricator or use a GFR400-C1 filter regulator on its own.

Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C15NW FAQ

AirTAC publishes flow for the G-series as curves, not as a single rated figure, so there is no one number we can honestly quote. This size 400 unit with its 1/2 in port serves the upper-middle of the family's flow range. Send us your flow demand and we will confirm the datasheet curves and figures for this exact model on request.

The 40 um grade is the default and suits general plant air for cylinders, valves and blow-off. The 5 um element selected by the W in this code is for finer air quality, for example when the same supply feeds spray equipment, instrumentation or sensitive pneumatic components. If part of your circuit needs fine air and part does not, we can help you split the supply across two sets.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFC Copper-Free Air Source Treatment Component B52-GFC400C15NW

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFC400C15NW and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.