verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart1 Request a QuoteQuote
AirTAC GFR200 · Filter Regulator (filter + regulator in one body)

Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR20008MC3WK

The AirTAC B52-GFR Copper-Free Air Treatment Unit B52-GFR20008MC3WK is a genuine G-series filter regulator: water separation, 5 µm particulate filtration and balanced-type pressure regulation combined in a single body. It has PT1/4" ports, a manual drain and regulates 0.05 - 0.9 MPa (7 - 130 psi). It does not lubricate — add a GL lubricator, or order the GFC two-unit set, if downstream equipment needs oil.

  • TypeFilter regulator
  • Port sizePT1/4"
  • Regulating range0.05 - 0.9 MPa (7 - 130 psi)
  • Filtering grade5 µm
  • DrainManual drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$64.97 $70.27Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR20008MC3WK

The AirTAC GFR20008MC3WK is a combined filter regulator: it removes water and particulate from compressed air and holds downstream pressure steady in one compact 200-size body. This configuration carries a PT1/4 port, a manual drain bowl, a 5 um (finer) filter element, an external round pressure gauge reading in bar, and a built-in reverse (check) valve that holds downstream pressure if the supply is interrupted. Max inlet pressure is 1.0 MPa (145 psi) and the manual-drain regulator adjusts from 0.05 to 0.9 MPa (7-130 psi). Operating temperature is -5 to 70 C, non-freezing.

This is a genuine AirTAC part from the G series, which spans 200, 300, 400 and 600 sizes with wider ports for higher flow, plus choices of drain type, filter grade, gauge style and G (BSPP) or NPT thread on request. Because AirTAC publishes flow only as curves rather than a single rating, we confirm exact flow and datasheet figures for your application on request.

Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR20008MC3WK Technical Specifications

ModelAirtac B52-GFR Copper-Free Air Treatment Unit B52-GFR20008MC3WK
SeriesGFR200 filter regulator
Port sizePT1/4" (PT thread)
Filtering grade5 µm
Regulating range0.05 - 0.9 MPa (7 - 130 psi)
Pressure typeStandard type
Adjusting mechanismBalanced type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeManual drain
Bowl materialPC
Pressure gaugeFitted — round, bar scale
Reflux valveFitted (reverse flow permitted)

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.05 - 0.9 MPa (7 - 130 psi). Air must not freeze in the unit. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR20008MC3WK

GFR200G-series filter regulator, 200 body — sets the port range.
08Port size PT1/4". This body offers 06 = PT1/8", 08 = PT1/4".
MDrain: Manual drain — this also sets the regulating band (0.05 - 0.9 MPa (7 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Mounting bracket included.
(blank)Pressure gauge fitted (blank).
CGauge shape: Round. C is round, F is square.
3Gauge scale: bar. 1 is MPa, 2 is psi, 3 is bar.
WFiltering grade 5 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
KReverse-flow (reflux) valve fitted.

Field order is size, port, drain, type, bracket, gauge, shape, scale, grade, thread, reflux — a blank position takes the default. Example: GFR300-08 is a 300 body, PT1/4", differential drain, standard type, bracket included, gauge fitted, 40 µm, PT thread, no reflux valve.

Size Class

  • GFR200PT1/8" - PT1/4"
  • GFR300PT1/4" - PT1/2"
  • GFR400PT3/8" - PT1/2"
  • GFR600PT3/4" - PT1"

A larger body carries a larger port and holds set pressure better as flow rises. AirTAC publishes flow only as curves, so size the body from your peak demand with headroom. The GFR600 uses an aluminium-alloy bowl; the 200, 300 and 400 bodies use PC.

This modelGFR200 · PT1/4" · 5 µm
One size upGFR300
Add lubricationGFC200-08 (two-unit set)

Where the Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR20008MC3WK Is Used

precision_manufacturing

Pneumatic clamping on CNC fixtures

Filtering and regulating the air that actuates workholding clamps on a machining centre, with the check valve holding clamp pressure if shop supply drops mid-cycle.

view_module

Clean-air feed to pick-and-place modules

Conditioning supply air for small vacuum and gripper modules on electronics assembly cells, where the 5 um element protects fine orifices and valves.

science

Laboratory bench instrumentation

Supplying steady, filtered air to lab analysers and test rigs, with the bar-scale gauge giving a direct local pressure readout at the bench.

Is the Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR20008MC3WK the Right Unit?

Size 200 with a PT1/4 port is the compact entry step of the G series; if your line draws more air, step up to size 300 (PT3/8) or size 400 (PT1/2) rather than oversizing a single unit. The 5 um element suits finer points of use such as instrumentation and spray work; the standard 40 um element is enough for general shop-air protection. The round bar-scale gauge here is the external option - an embedded square gauge is also available - and the built-in check valve is worth keeping if the downstream circuit must not lose pressure on supply loss.

AirTAC publishes flow as curves, not a single rated figure, so send us your flow and pressure requirements and we will confirm sizing against the datasheet before you order. PT is the standard thread; G (BSPP) and NPT are catalogue options you can specify when ordering.

Quick checklist

  • ✓ Body size for your peak flow (PT1/4" here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Thread PT, G (BSPP) or NPT
  • ✓ Oil needed downstream? Use GFC instead
Ask an Engineer

Installation & Maintenance Notes

  • check Mount vertically, bowl down, following the airflow arrow.
  • check One body does the filtering and the regulating — no separate regulator needed.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.05 - 0.9 MPa (7 - 130 psi).
  • check Drain condensate before the bowl fills.
  • check Keep the unit above freezing (-5 to +70 °C, unfreeze).

The PC bowl must not be cleaned with solvents — wipe it with a dry cloth. The reflux valve permits reverse flow through the unit. A filter regulator adds no oil to the line.

Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR20008MC3WK FAQ

AirTAC publishes flow for this unit as performance curves rather than a single rated number, so there is no one figure we can quote honestly. Tell us your flow and pressure conditions and we will confirm the correct size from the datasheet on request.

The M in the code sets a manual drain, so condensate is emptied by hand rather than automatically - right for cabinets or intermittent-duty points where an auto drain is unnecessary. The K adds a reverse (check) valve that holds downstream pressure if the upstream supply fails, useful for clamping and holding circuits.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac B52-GFR Copper-Free Air Treatment Unit B52-GFR20008MC3WK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for B52-GFR20008MC3WK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.