verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC BFC2000 · Two-Unit (Filter-Regulator + Lubricator) (compact A/B line)

Airtac BFC F.R.L Pneumatic Air Filter BFC2000M1

The AirTAC BFC F.R.L Pneumatic Air Filter BFC2000M1 is a genuine A/B-line two-unit F.R.L. set with PT1/4" ports. It is the compact air-preparation line, regulating 0.15 - 0.9 MPa (20 - 130 psi) with a push-to-lock knob and oil-mist lubrication with a transparent sight dome. Flow is confirmed from the datasheet on request.

  • TypeTwo-Unit (Filter-Regulator + Lubricator)
  • Line / sizeB-line, 2000
  • Port sizePT1/4"
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filter grade40 um / 5 um (W)
  • Max inlet pressure1.0 MPa (145 psi)
  • Temperature-5 to +70 C (non-freezing)
  • ThreadPT
$65.34
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac BFC F.R.L Pneumatic Air Filter BFC2000M1

The BFC2000M1 is a two-unit air preparation set for 1/4 in PT ports: a compact B-line filter-regulator combined with a lubricator. The filter section uses the standard 40 um element, and the M suffix selects the manual drain - condensate stays in the polycarbonate (PC) bowl until an operator opens it, which suits stations on a defined maintenance routine. The regulator section carries an MPa-scale pressure gauge and a push-to-lock self-locking knob; regulation spans 0.15-0.9 MPa (20-130 psi) with a 1.0 MPa (145 psi) maximum working pressure. The lubricator shows its oil drip rate through a transparent sight dome.

This is a genuine AirTAC part from the compact B line, the larger of the two compact A/B bodies. The same two-unit layout is offered in 1/8 in, 1/4 in, 3/8 in and 1/2 in port sizes, with G (BSPP) and NPT threads available as order options where PT is not wanted. Flow figures are not published as a single rated number, so ask us to confirm sizing and request the datasheet for your operating point.

Airtac BFC F.R.L Pneumatic Air Filter BFC2000M1 Technical Specifications

ModelAirtac BFC F.R.L Pneumatic Air Filter BFC2000M1
TypeTwo-Unit (Filter-Regulator + Lubricator)
LineB-line (compact A/B air preparation)
Port sizePT1/4" (PT thread)
Filter grade40 um standard, 5 um optional (W)
Regulating range0.15 - 0.9 MPa (20 - 130 psi) (low-pressure type to 0.4 MPa)
FluidCompressed air
Max. inlet pressure1.0 MPa (145 psi)
Temperature range-5 to +70 C (non-freezing)
Bowl materialPC (polycarbonate)
LubricationOil-mist, transparent sight dome
Pressure dropLow (catalogue-stated)

Specifications follow the official AirTAC A/B-line air-preparation data. Drain type, filter grade, gauge and low-pressure options are set by the model-code suffix - see the description. Flow curves, weight and outline dimensions are not published in our data set — ask us and we confirm from the factory datasheet.

How to choose

The B-line 1/4 in body suits circuits that need the larger compact frame above the A-line class - confirm your required flow with us first, as these units have no single published rated flow figure. The M suffix gives you a manual drain; choose the A automatic-drain version instead if the station cannot be visited for bowl emptying. The 40 um element is standard, with a 5 um (W) grade available. The gauge here reads in MPa; scales in psi, bar or kgf/cm2 and psi can be specified instead, and the low-pressure L type is the choice if your circuit is capped at 0.4 MPa. PT is the standard thread; G and NPT are order options.

Applications

conveyor_belt

Diverting and sorting gates on conveyor lines

Prepares the air for pneumatic pushers and divert gates that sort product between lanes: 40 um filtration, a stable regulated pressure and oil mist for the cylinders, with the manual drain emptied on the line's scheduled maintenance walk.

science

Pneumatic test benches in R&D and QC labs

Feeds leak-test and cycle-test stations with clean, regulated, lubricated air. The MPa gauge and self-locking knob hold the test pressure through a run, and the sight dome confirms oil delivery before a long endurance test starts.

settings_input_component

Valve and actuator supply inside control panels

Mounted at the air inlet of a machine's pneumatic manifold to protect downstream directional valves and actuators, giving the panel a single filtered, regulated and lubricated supply point for all its solenoid-fed branches.

FAQ

How much air can the BFC2000M1 flow?

Flow for the compact B-line two-unit sets is not published as a single rated figure. Send us your operating pressure and air consumption and we will confirm the datasheet figures and correct sizing on request before you order.

What do the M and the trailing 1 in the model code mean?

M selects the manual drain: you empty condensate from the PC bowl yourself rather than relying on an automatic drain. The trailing 1 is the gauge scale - 1 means the included pressure gauge reads in MPa. Scale 2 gives psi, 3 gives bar, and 4 gives kgf/cm2 and psi.