Genuine AirTAC iso valve base, order code ESV401MGB from the ESV400-BASE range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
A one-station ISO 5599-1 mounting base for the ESV4x0 solenoid and EAV4x0 air-piloted 400-series valves. The B option takes the PT1/2 working ports out of the bottom of the body, and the G marking specifies G (BSPP) thread instead of the standard PT.
Because this is a single base (1M), the external pilot port is independent, feeding the one valve directly. The exhaust throttle is built in: turn its adjusting screw clockwise with a hex key to cut exhaust flow, so no separate speed controller is needed. Proof pressure is 1.5 MPa (215 psi) over a -20 to +70 C range on air filtered by a 40 um element.
| Order code | ESV401MGB |
|---|---|
| Product | ISO Valve Base |
| Part | Single base (1M) |
| Ports and pilot | Bottom ports (B) |
| Port thread | G (BSPP) |
| Parts | Single base (1M), Manifold base (2M), End plate set (3M) |
|---|---|
| Working ports | PT1/2 |
| End-plate ports | PT3/4 |
| Mounting face | ISO 5599-1 |
| Fluid | Air (filtered by 40 µm element) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -20 to +70 °C |
| Exhaust throttle | Built in |
Source: AirTAC Products Catalog 2026A (PDF01-P0094..P0096), ESV200/300/400/600 series specifications and ordering code.
Pick ESV401MGB over its siblings on two axes. Against ESV401M and ESV401MG (side ports), the B option suits panels where piping rises from below the base; against ESV401MB, this code swaps PT for G thread. If you later need more than one valve on a common supply, move to ESV402M manifold bases plus an ESV403M end plate set rather than stacking single bases.
Feed one 400-series valve on a machine base where hose routing comes up through the mounting plate; G thread mates with BSPP fittings common on export machinery.
Use the built-in exhaust throttle to control a small actuator's exhaust directly at the base instead of adding inline speed controllers near the cylinder.
Replace a worn single base on equipment built to the ISO 5599-1 mounting face where the original ports were specified in G thread and exit downward.
Single base (1M) with bottom (B) working ports in G thread, PT1/2 port size, ISO 5599-1 mounting face, proof pressure 1.5 MPa (215 psi), temperature -20 to +70 C, air filtered by a 40 um element, exhaust throttle built in.
Turn the adjusting screw of the built-in exhaust throttle with a hex key; clockwise reduces the exhaust flow. The valve's external pilot is fed through the independent pilot port of this single base.