Genuine AirTAC iso valve base, order code ESV402MB from the ESV400-BASE range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
In a bank of 2M bases, this station sends its PT1/2 working ports out of the bottom face instead of the left side, so tubing can drop straight down to the actuators beneath the manifold. It carries any ISO 5599-1 ESV4x0 solenoid or EAV4x0 air-piloted 400-series valve.
The pilot arrangement is the independent type: every station has its own external pilot port rather than sharing a centralized W feed from the end plate. Thread is standard PT (add the G suffix for G thread), and each base contains an exhaust throttle adjusted with a hex key, clockwise to reduce flow. Unused bottom ports in the stack are closed with plugs.
| Order code | ESV402MB |
|---|---|
| Product | ISO Valve Base |
| Part | Manifold base (2M) |
| Ports and pilot | Bottom ports (B) · independent pilot |
| Port thread | PT |
| Parts | Single base (1M), Manifold base (2M), End plate set (3M) |
|---|---|
| Working ports | PT1/2 |
| End-plate ports | PT3/4 |
| Mounting face | ISO 5599-1 |
| Fluid | Air (filtered by 40 µm element) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -20 to +70 °C |
| Exhaust throttle | Built in |
Source: AirTAC Products Catalog 2026A (PDF01-P0094..P0096), ESV200/300/400/600 series specifications and ordering code.
Choose ESV402MB when piping must leave the manifold vertically; ESV402M and ESV402MR serve left- and right-facing runs. The W option replaces the independent pilot with a single centralized supply through the end plate, and the G suffix changes PT to G thread. The ESV403M end plate set is never included with the bases, so order one set per manifold.
Run PT1/2 lines from the underside of the manifold straight to cylinders mounted below, leaving the top of the bank unobstructed for valve installation and service.
Mount the bank along a conveyor frame and drop air lines to diverters and stops at low level, one station per function with independent pilot signals.
Group clamp, seal and eject valves on one manifold; bottom ports let hoses run inside the machine frame instead of along its sides.
Manifold base (2M) with bottom (B) working ports, PT1/2 port size, PT thread, independent external pilot port, ISO 5599-1 mounting face, proof pressure 1.5 MPa (215 psi), temperature -20 to +70 C, exhaust throttle built in.
When a station does not use its bottom working ports, close them with plugs as the series notes specify. The ESV403M end plate set, with its one-size-larger PT3/4 supply and exhaust ports, terminates the manifold.