Genuine AirTAC iso valve base, order code ESV402MGB from the ESV400-BASE range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
The order code ESV402MGB decodes to a 400-series ISO 5599-1 manifold base (2M) with bottom working ports (B) and G thread. Each 2M base carries one ESV4x0 solenoid valve or EAV4x0 air-piloted valve, and its 1/2 working port exits underneath the station, so tubing can run below the manifold while coils and manual overrides stay accessible on top. Proof pressure is 1.5 MPa (215 psi) across a temperature range of -20 to +70 C.
The independent external pilot port feeds each station separately, which suits mixed valve logic assembled on one manifold. The built-in exhaust throttle is turned with a hex key, clockwise to reduce exhaust flow, so cylinder speed can be set without a separate speed controller between base and actuator. Any unused bottom port is closed with a plug.
| Order code | ESV402MGB |
|---|---|
| Product | ISO Valve Base |
| Part | Manifold base (2M) |
| Ports and pilot | Bottom ports (B) · independent pilot |
| Port thread | G (BSPP) |
| Parts | Single base (1M), Manifold base (2M), End plate set (3M) |
|---|---|
| Working ports | PT1/2 |
| End-plate ports | PT3/4 |
| Mounting face | ISO 5599-1 |
| Fluid | Air (filtered by 40 µm element) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -20 to +70 °C |
| Exhaust throttle | Built in |
Source: AirTAC Products Catalog 2026A (PDF01-P0094..P0096), ESV200/300/400/600 series specifications and ordering code.
Choose ESV402MGB when port access from underneath the manifold matters; if tubing should run along the side, order ESV402MGR for right-facing ports instead (blank position = left). Compared with the single base ESV401MG, this 2M base lets you grow the bank one valve at a time, closed off by an ESV403MG end plate set whose supply and exhaust ports step up one size to 3/4. PT thread is the catalog standard; the G in the code fixes BSPP.
Route the 1/2 G working ports downward through a machine base so the valve faces and coil area on top of the manifold remain clear.
Set each actuator's exhaust flow directly at the built-in throttle with a hex key, clockwise to reduce flow, with no extra speed controllers to buy or plumb.
Mount ESV4x0 or EAV4x0 valves station by station on 2M bases and give every externally piloted station its own independent pilot feed.
Manifold base (2M) for ISO 5599-1 valves, with 1/2 working ports in G (BSPP) thread exiting at the bottom and an independent external pilot port. Proof pressure 1.5 MPa (215 psi), temperature -20 to +70 C, air filtered by a 40 um element, and a built-in exhaust throttle adjusted with a hex key.
One ESV402MGB per valve plus one ESV403MG end plate set to close the assembled manifold; the end plate's supply and exhaust ports are one size larger (3/4). Close any unused bottom port with a plug.