Genuine AirTAC iso valve base, order code ESV402MGR from the ESV400-BASE range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
With R in its code, the ESV402MGR is the 400-series ISO 5599-1 manifold base whose 1/2 G-thread working ports face right, combined with an independent external pilot port. One ESV4x0 solenoid valve or EAV4x0 air-piloted valve mounts per station, and 2M bases bolt together into a manifold of any length. Proof pressure is 1.5 MPa (215 psi) over -20 to +70 C.
Right-facing ports keep the tubing runs on one side of the machine, leaving the opposite face free for coils, wiring and access. Each station still receives its own pilot feed, and the built-in exhaust throttle turns clockwise with a hex key to reduce exhaust flow. Supply the base with air filtered by a 40 um element.
| Order code | ESV402MGR |
|---|---|
| Product | ISO Valve Base |
| Part | Manifold base (2M) |
| Ports and pilot | Right ports (R) · independent pilot |
| Port thread | G (BSPP) |
| Parts | Single base (1M), Manifold base (2M), End plate set (3M) |
|---|---|
| Working ports | PT1/2 |
| End-plate ports | PT3/4 |
| Mounting face | ISO 5599-1 |
| Fluid | Air (filtered by 40 µm element) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -20 to +70 °C |
| Exhaust throttle | Built in |
Source: AirTAC Products Catalog 2026A (PDF01-P0094..P0096), ESV200/300/400/600 series specifications and ordering code.
Pick ESV402MGR over ESV402MGB when tubes should leave horizontally rather than down through the manifold floor; the left-port layout is the default when no position letter is given. Since the pilot port here is independent, every station is fed separately; for one common pilot line from the end plate, order ESV402MGW instead. Match the bank with the ESV403MG end plate set in G thread.
Run the 1/2 G working ports horizontally along one machine wall while the other side of the manifold stays open for coil replacement and inspection.
Group ESV4x0 valves on 2M bases to drive diverters and stops along a line, tuning each exhaust at the built-in hex-key throttle.
Because the pilot port is independent, externally piloted stations on the same manifold can each take a separate pilot supply without extra plates.
ISO 5599-1 manifold base (2M) with 1/2 working ports in G (BSPP) thread facing right and an independent external pilot port. Proof pressure 1.5 MPa (215 psi), temperature -20 to +70 C, 40 um air filtration, and a built-in exhaust throttle set clockwise with a hex key.
ESV4x0 solenoid valves and EAV4x0 air-piloted valves with the ISO 5599-1 mounting face, one valve per 2M base. Finish the assembled manifold with the ESV403MG end plate set, whose supply and exhaust ports are one size larger (3/4).