verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC ESV400-BASE · ISO Valve Base

Airtac ESV-M Base ESV402MGW

Genuine AirTAC iso valve base, order code ESV402MGW from the ESV400-BASE range. The options this code selects are decoded below; series data follow the official AirTAC catalog.

  • PartManifold base (2M)
  • Ports and pilotLeft ports · centralized pilot (W)
  • Port threadG (BSPP)
  • PartsSingle base (1M), Manifold base (2M), End plate set (3M)
  • Working portsPT1/2
  • End-plate portsPT3/4
$39.51 $47.01Save 15%
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Shipped from our own warehouse: most standard models dispatch in 3–5 days; custom and non-standard models take 8–10 business days. Transit time after that depends on the destination.
Compare every ESV400-BASE part, ports and pilot and port thread on one page All ESV400-BASE codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7 h

About the Airtac ESV-M Base ESV402MGW

ESV402MGW decodes to a 400-series ISO 5599-1 manifold base with working ports on the left (the default position) in G thread and a centralized external pilot port (W). Instead of running a pilot line to every station, the whole manifold is fed from a single pilot connection at the end plate, which cuts tubing and fittings on long multi-valve banks.

Each 2M base carries one ESV4x0 solenoid or EAV4x0 air-piloted valve with its 1/2 working port exiting left. Proof pressure is 1.5 MPa (215 psi) and the fluid is air filtered by a 40 um element, from -20 to +70 C. Close the assembled manifold with an ESV403MG end plate set, whose supply and exhaust ports are one size larger (3/4), and tune each exhaust at the built-in hex-key throttle, clockwise for less flow.

Airtac ESV-M Base ESV402MGW Technical Specifications

Order codeESV402MGW
ProductISO Valve Base
PartManifold base (2M)
Ports and pilotLeft ports · centralized pilot (W)
Port threadG (BSPP)
PartsSingle base (1M), Manifold base (2M), End plate set (3M)
Working portsPT1/2
End-plate portsPT3/4
Mounting faceISO 5599-1
FluidAir (filtered by 40 µm element)
Proof pressure1.5 MPa (215 psi)
Temperature-20 to +70 °C
Exhaust throttleBuilt in

Source: AirTAC Products Catalog 2026A (PDF01-P0094..P0096), ESV200/300/400/600 series specifications and ordering code.

How to choose

Order ESV402MGW when one common pilot supply for the entire manifold beats per-station pilot feeds; otherwise take ESV402MGR or ESV402MGB, which keep the pilot port independent. Left ports need no position letter in the code. Add one ESV403MG end plate set per manifold, and note that a single-valve setup can use the ESV401MG single base instead of a 2M station.

Applications

cable

One pilot supply for the bank

Feed all externally piloted stations from a single connection at the end plate rather than tubing every base separately.

precision_manufacturing

Growing valve banks

Bolt 2M bases into a manifold of any length and add or swap ISO 5599-1 valves as the station count on the line increases.

straighten

Tidy cabinet-side installs

Left-facing 1/2 G ports let the tubing exit away from coil and wiring space, with exhaust speed set locally at each built-in throttle.

FAQ

What are the key figures of the ESV402MGW?

ISO 5599-1 manifold base (2M) with left-side 1/2 working ports in G (BSPP) thread and a centralized external pilot port fed from the end plate. Proof pressure 1.5 MPa (215 psi), temperature -20 to +70 C, air filtered by a 40 um element, built-in hex-key exhaust throttle.

When does the centralized pilot (W) matter?

The pilot connection is relevant only to externally piloted valves; with W, the whole manifold takes one pilot supply at the end plate instead of an independent port per station. Close the bank with an ESV403MG end plate set, whose supply and exhaust ports are one size larger (3/4).