Genuine AirTAC iso valve base, order code ESV402MGW from the ESV400-BASE range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
ESV402MGW decodes to a 400-series ISO 5599-1 manifold base with working ports on the left (the default position) in G thread and a centralized external pilot port (W). Instead of running a pilot line to every station, the whole manifold is fed from a single pilot connection at the end plate, which cuts tubing and fittings on long multi-valve banks.
Each 2M base carries one ESV4x0 solenoid or EAV4x0 air-piloted valve with its 1/2 working port exiting left. Proof pressure is 1.5 MPa (215 psi) and the fluid is air filtered by a 40 um element, from -20 to +70 C. Close the assembled manifold with an ESV403MG end plate set, whose supply and exhaust ports are one size larger (3/4), and tune each exhaust at the built-in hex-key throttle, clockwise for less flow.
| Order code | ESV402MGW |
|---|---|
| Product | ISO Valve Base |
| Part | Manifold base (2M) |
| Ports and pilot | Left ports · centralized pilot (W) |
| Port thread | G (BSPP) |
| Parts | Single base (1M), Manifold base (2M), End plate set (3M) |
|---|---|
| Working ports | PT1/2 |
| End-plate ports | PT3/4 |
| Mounting face | ISO 5599-1 |
| Fluid | Air (filtered by 40 µm element) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -20 to +70 °C |
| Exhaust throttle | Built in |
Source: AirTAC Products Catalog 2026A (PDF01-P0094..P0096), ESV200/300/400/600 series specifications and ordering code.
Order ESV402MGW when one common pilot supply for the entire manifold beats per-station pilot feeds; otherwise take ESV402MGR or ESV402MGB, which keep the pilot port independent. Left ports need no position letter in the code. Add one ESV403MG end plate set per manifold, and note that a single-valve setup can use the ESV401MG single base instead of a 2M station.
Feed all externally piloted stations from a single connection at the end plate rather than tubing every base separately.
Bolt 2M bases into a manifold of any length and add or swap ISO 5599-1 valves as the station count on the line increases.
Left-facing 1/2 G ports let the tubing exit away from coil and wiring space, with exhaust speed set locally at each built-in throttle.
ISO 5599-1 manifold base (2M) with left-side 1/2 working ports in G (BSPP) thread and a centralized external pilot port fed from the end plate. Proof pressure 1.5 MPa (215 psi), temperature -20 to +70 C, air filtered by a 40 um element, built-in hex-key exhaust throttle.
The pilot connection is relevant only to externally piloted valves; with W, the whole manifold takes one pilot supply at the end plate instead of an independent port per station. Close the bank with an ESV403MG end plate set, whose supply and exhaust ports are one size larger (3/4).