Genuine AirTAC iso valve base, order code ESV402MGWB from the ESV400-BASE range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
ESV402MGWB specifies the 2M manifold base of the AirTAC ESV400 series with bottom working ports, a centralized external pilot and G (BSPP) thread. It seats one ISO 5599-1 valve, either an ESV4x0 solenoid valve or an EAV4x0 air-piloted valve, and delivers the PT1/2-size working ports from below. Several 2M bases bolt together into a manifold of any number of stations, sealed at the end by a 3M end plate set whose supply and exhaust ports are one size larger, PT3/4.
The W in the code means the external pilot supply enters once at the end plate and feeds every station on the manifold, instead of each base taking its own pilot connection. Air must be filtered by a 40 um element, and the base withstands a 1.5 MPa (215 psi) proof pressure between -20 and +70 C. Each station carries a built-in exhaust throttle: turn the adjusting screw clockwise with a hex key to reduce exhaust flow, so no separate speed controller is needed. Plug any bottom port left unused.
| Order code | ESV402MGWB |
|---|---|
| Product | ISO Valve Base |
| Part | Manifold base (2M) |
| Ports and pilot | Bottom ports (B) · centralized pilot (W) |
| Port thread | G (BSPP) |
| Parts | Single base (1M), Manifold base (2M), End plate set (3M) |
|---|---|
| Working ports | PT1/2 |
| End-plate ports | PT3/4 |
| Mounting face | ISO 5599-1 |
| Fluid | Air (filtered by 40 µm element) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -20 to +70 °C |
| Exhaust throttle | Built in |
Source: AirTAC Products Catalog 2026A (PDF01-P0094..P0096), ESV200/300/400/600 series specifications and ordering code.
Pick this code over ESV402MGWR when the valve island is pipe-dropped from below, since R points the same G ports to the right instead. Choose it over ESV402MR, which shares the right-port layout but uses standard PT thread and an independent pilot port per station, when you prefer BSPP fittings and a single pilot feed for the whole manifold.
Externally piloted EAV4x0 valves on a machine manifold take their pilot supply from one line at the end plate, so the whole island runs on a single pilot feed instead of one connection per station.
Bottom G ports let supply and cylinder hoses leave the manifold downward, keeping the ISO 5599-1 mounting face and side clearance free for valve replacement.
The built-in exhaust throttle is set station by station with a hex key, clockwise to slow cylinder return, without adding separate speed controllers to the PT1/2-size circuit.
Manifold base (2M) for one ISO 5599-1 valve; bottom working ports in G (BSPP) thread at PT1/2 size; centralized external pilot (W); proof pressure 1.5 MPa (215 psi); temperature -20 to +70 C; air filtered by a 40 um element; 3M end plate set ports PT3/4; built-in exhaust throttle on every station.
With W, one external pilot supply is connected once at the manifold end plate and distributed to all stations, which simplifies piping on multi-valve islands. With an independent pilot port, each base is fed separately. The distinction only matters for externally piloted EAV4x0 valves; ESV4x0 solenoid valves do not draw on the pilot port.