Genuine AirTAC iso valve base, order code ESV402MGWR from the ESV400-BASE range. The options this code selects are decoded below; series data follow the official AirTAC catalog.
On the ESV402MGWR the R option turns the G (BSPP) working ports of this 2M manifold base to the right-hand side, the position you need when the valve island stands against a machine wall and piping must leave sideways. The base mounts one ISO 5599-1 valve, an ESV4x0 solenoid valve or an EAV4x0 air-piloted valve, and its working ports are PT1/2 size. Manifolds of any length are built by bolting 2M bases together and finishing with one 3M end plate set.
W marks the centralized external pilot: the pilot supply is connected once at the end plate and reaches every station from there, rather than each base carrying its own pilot connection. The G suffix fixes the thread as G instead of the PT standard. The base takes a 1.5 MPa (215 psi) proof pressure across -20 to +70 C on air filtered by a 40 um element, and each station has a built-in exhaust throttle adjusted with a hex key, clockwise to cut exhaust flow.
| Order code | ESV402MGWR |
|---|---|
| Product | ISO Valve Base |
| Part | Manifold base (2M) |
| Ports and pilot | Right ports (R) · centralized pilot (W) |
| Port thread | G (BSPP) |
| Parts | Single base (1M), Manifold base (2M), End plate set (3M) |
|---|---|
| Working ports | PT1/2 |
| End-plate ports | PT3/4 |
| Mounting face | ISO 5599-1 |
| Fluid | Air (filtered by 40 µm element) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature | -20 to +70 °C |
| Exhaust throttle | Built in |
Source: AirTAC Products Catalog 2026A (PDF01-P0094..P0096), ESV200/300/400/600 series specifications and ordering code.
This code differs from ESV402MGWB only in port position: the WB variant sends the same G ports out of the bottom of the base. Compared with ESV402MR, which also points ports right, this G version accepts BSPP fittings and, as a W code, shares one centralized pilot instead of an independent port on every station.
With the manifold bolted flat against the machine side, hoses to conveyor cylinders route out of the right-face ports along the frame instead of dropping under the base.
Machines built around several externally piloted EAV4x0 valves pipe the pilot supply once at the 3M end plate, and the W manifold distributes it to every station.
Where the existing machine piping uses G fittings at the PT1/2 port size, the G suffix matches the thread without adaptors on the ISO 5599-1 mounting face.
2M manifold base for one ISO 5599-1 valve; right-side (R) working ports in G (BSPP) thread at PT1/2 size; centralized external pilot (W) fed from the end plate; proof pressure 1.5 MPa (215 psi); temperature -20 to +70 C; air filtered by a 40 um element; built-in exhaust throttle; end plate set ports PT3/4.
It carries any ESV4x0 solenoid valve or EAV4x0 air-piloted valve with the ISO 5599-1 mounting face. Build a multi-station island by bolting further 2M bases alongside and closing the row with one 3M end plate set, whose supply and exhaust ports are one size larger, PT3/4.