verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
AirTAC GAR300 · Air Pressure Regulator

Airtac GAR Air Regulator GAR30015LJN

The AirTAC Airtac GAR Air Regulator GAR30015LJN is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.4 MPa range, with 1/2" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.

  • TypeAir regulator
  • Port size1/2"
  • Pressure range0.05 - 0.4 MPa
  • RegulationLower pressure
  • GaugeNone (N)
  • Reflux valveNo
  • Max pressure1.0 MPa
  • Weight300 g
$27.51 $33.05Save 16% Standard model — usually ships in 3-4 days
Request a Quote
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GAR Air Regulator GAR30015LJN

The GAR30015LJN is an air pressure regulator that takes a higher supply pressure and holds a steady lower downstream pressure you set with the knob. It does not filter or clean the air; it only regulates pressure. This unit has a 1/2in port, weighs 300 g, and is the lower-pressure type with a regulated range of 0.05-0.4 MPa (7-58 psi).

The pressed-in self-locking knob prevents the set pressure from drifting due to vibration or accidental knocks, keeping your downstream equipment stable. With no gauge fitted, you read the pressure on the line's own panel gauge. The balanced adjustment mechanism helps the regulator hold its setting as supply pressure varies.

Airtac GAR Air Regulator GAR30015LJN Technical Specifications

ModelAirtac GAR Air Regulator GAR30015LJN
SeriesGAR300 air regulator
Port size1/2" (PT thread)
Regulation typeLower pressure
Pressure range0.05 - 0.4 MPa (7 - 58 psi)
Pressure gaugeNone (N) — MPa / psi port
BracketNot included (J)
Reflux valveNone
FluidAir
Max. pressure1.0 MPa (145 psi)
Proof pressure1.5 MPa (215 psi)
Temperature range-20 to +70 °C
AdjustmentSelf-locking press-in knob
MountingPanel + optional bracket
Weight300 g

Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR300 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.

Model Code: Airtac GAR Air Regulator GAR30015LJN

GAR300GA300 series air regulator — sets the port range and weight class.
15Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2".
LLower pressure regulation: 0.05 - 0.4 MPa (7 - 58 psi). This body offers S (standard) or L (lower pressure).
JNo bracket (J) — panel mount or existing bracket.
NNo gauge (N) — for a line with a panel gauge already.
(blank)PT thread; gauge scale MPa / psi.
(blank)No reverse-flow (reflux) valve.

A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR300-15 is the same regulator with a built-in filter.

Size Class

  • GAR2001/8"-1/4" · 170 g
  • GAR3001/4"-1/2" · 300 g
  • GAR4003/8"-1/2" · 570 g
  • GAR5003/4" · 580 g
  • GAR6003/4"-1" · 1390 g

All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.

This modelGAR300 · 1/2" · 300 g
One size downGAR200
One size upGAR400
Add filtrationGAFR300-15 (filter + regulator)

Where the Airtac GAR Air Regulator GAR30015LJN Is Used

precision_manufacturing

Low-pressure pneumatic clamping

Set a gentle, repeatable clamp force on delicate parts in assembly fixtures. The 0.05-0.4 MPa range gives fine control for light-duty holding without damaging components.

science

Lab air supply regulation

Feed a steady low-pressure air supply to laboratory instruments or test rigs. The lower range and self-locking knob keep the setpoint stable during experiments.

tune

Precision painting or coating

Regulate air for spray application where consistent low pressure matters. The balanced design holds the setting as the supply fluctuates, supporting even coating results.

Is the Airtac GAR Air Regulator GAR30015LJN the Right Regulator?

Choose the GAR30015LJN when you need a 1/2in port regulator for lower-pressure applications. The L type regulates only 0.05-0.4 MPa (7-58 psi), which is ideal for fine control in low-pressure circuits but cannot reach a 0.5-0.6 MPa setpoint. This model has no bracket (J), so plan for panel mounting or use an existing bracket; it also has no gauge (N), so rely on a line gauge. The PT thread reads MPa/psi on the gauge scale. If the air also needs cleaning, use a GAFR300-15 or a separate GAF filter upstream. The standard S type spans about 2.4x this L type's adjustable band (0.85 MPa vs 0.35 MPa).

Quick checklist

  • ✓ Body size for your air demand (1/2" here)
  • ✓ Type S (0.05-0.9) or L (0.05-0.4 MPa)
  • ✓ Gauge fitted, or no gauge (N)
  • ✓ Thread PT / G / NPT (sets gauge scale)
  • ✓ Bracket kept or removed (J)
  • ✓ Need filtration too? Use GAFR300
Ask an Engineer

Installation & Setting Notes

  • check Install with the airflow arrow: IN to OUT, knob accessible.
  • check Put a filter (GAF or a GAFR) UPSTREAM — a regulator does not clean the air.
  • check Set pressure by turning the knob up to the target, then press it in to lock.
  • check Keep supply at or below the 1.0 MPa (145 psi) max working pressure.
  • check Never exceed the 1.5 MPa (215 psi) proof pressure.
  • check Support the 300 g unit on its panel or bracket, not on the tubing.

This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR300-15 filter-regulator as your air-prep needs grow.

Airtac GAR Air Regulator GAR30015LJN FAQ

The GAR30015LJN is a lower-pressure regulator with a regulated range of 0.05-0.4 MPa (7-58 psi). Maximum supply pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), and temperature range is -20 to 70 C. It has a 1/2in port and weighs 300 g.

The N means no pressure gauge is fitted. You read the downstream pressure on the line's own panel gauge instead. This model also has no bracket (J), so it is designed for panel mounting or use with an existing bracket.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models usually ship in 3-4 days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GAR Air Regulator GAR30015LJN

Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.

Thank you. We received your request for GAR30015LJN and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.