The AirTAC GAR Air Regulator GAR30015LK is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.4 MPa range, with 1/2" ports and a built-in circular pressure gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR30015LK is a lower-pressure air regulator that takes a supply up to 1.0 MPa and holds a steady downstream setting between 0.05 and 0.4 MPa (7-58 psi). Its pressed-in self-locking knob keeps the setpoint stable against vibration and accidental knocks, so a calibrated low-pressure station stays where you left it. This 1/2in unit weighs 300 g and carries a circular gauge with a clip and magnifier for easy reading in tight panels.
This is a regulator only - it does not filter the air or remove water, oil or particles. A reverse-flow (reflux) valve is attached to this model. For clean air, fit a GAF300-15 filter-regulator or a separate GAF filter upstream; the GAR itself only controls pressure.
| Model | Airtac GAR Air Regulator GAR30015LK |
|---|---|
| Series | GAR300 air regulator |
| Port size | 1/2" (PT thread) |
| Regulation type | Lower pressure |
| Pressure range | 0.05 - 0.4 MPa (7 - 58 psi) |
| Pressure gauge | Circular, MPa / psi scale |
| Bracket | Included |
| Reflux valve | Attached (K) |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 300 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR300 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR300 | GA300 series air regulator — sets the port range and weight class. |
|---|---|
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| L | Lower pressure regulation: 0.05 - 0.4 MPa (7 - 58 psi). This body offers S (standard) or L (lower pressure). |
| (blank) | Mounting bracket included. |
| (blank) | Circular pressure gauge fitted. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached (K). |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR300-15 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR300 · 1/2" · 300 g |
|---|---|
| One size down | GAR200 |
| One size up | GAR400 |
| Add filtration | GAFR300-15 (filter + regulator) |
Set a stable 0.2 MPa pilot signal for a sequence of pneumatic valves. The L type's finer low-band resolution keeps the pilot pressure consistent even when the main supply fluctuates.
Regulate a gentle 0.1 MPa air stream for clearing debris off machined parts. The balanced design holds the low setpoint as the shop compressor cycles, protecting delicate workpieces.
Feed a controlled 0.3 MPa supply to a test fixture or analytical instrument. The self-locking knob prevents drift from bench vibrations, and the 1/2in port handles modest flow demands.
Choose the GAR300 body when your line needs a 1/2in port and a 300 g regulator that mounts on a panel or bracket. The L type regulates only 0.05-0.4 MPa, so it suits low-pressure circuits like pilot air or precision blow-off, not standard 0.5-0.6 MPa machine settings. The circular gauge reads MPa/psi on its PT thread, and the included bracket simplifies installation. The K code adds a reflux valve, named here without function detail. If the air also needs cleaning, step up to the GAFR300-15 filter-regulator instead. The S type spans about 2.4x this L type's adjustable band (0.85 MPa vs 0.35 MPa).
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR300-15 filter-regulator as your air-prep needs grow.
The GAR30015LK is a lower-pressure air regulator with a 1/2in port and a weight of 300 g. It regulates from 0.05 to 0.4 MPa (7-58 psi), handles a maximum supply pressure of 1.0 MPa (145 psi), and has a proof pressure of 1.5 MPa (215 psi). The operating temperature range is -20 to 70 C. It comes with a circular gauge reading MPa/psi and an included mounting bracket.
The K in GAR30015LK indicates a reverse-flow (reflux) valve is attached to the regulator. This is a factory-fitted option on the unit. The GAR itself remains a regulator only - it does not filter or clean the air. For filtration, use a GAFR300-15 or a separate GAF filter upstream.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.