The AirTAC Airtac GAR Air Regulator GAR30015LNK is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.4 MPa range, with 1/2" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR30015LNK is an air pressure regulator that takes a higher supply and holds a steady lower downstream pressure, set by the knob and read on the line's own panel gauge since this unit ships without one. It regulates pressure only - it does not filter, clean, dry, or remove water, oil, or particles from the air.
This lower-pressure (L) model regulates from 0.05-0.4 MPa (7-58 psi), with a 1/2in port and a 300 g body. The pressed-in self-locking knob prevents the set pressure from drifting due to vibration or accidental knocks, while the balanced adjustment mechanism holds the setting as supply pressure varies.
| Model | Airtac GAR Air Regulator GAR30015LNK |
|---|---|
| Series | GAR300 air regulator |
| Port size | 1/2" (PT thread) |
| Regulation type | Lower pressure |
| Pressure range | 0.05 - 0.4 MPa (7 - 58 psi) |
| Pressure gauge | None (N) — MPa / psi port |
| Bracket | Included |
| Reflux valve | Attached (K) |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 300 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR300 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR300 | GA300 series air regulator — sets the port range and weight class. |
|---|---|
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| L | Lower pressure regulation: 0.05 - 0.4 MPa (7 - 58 psi). This body offers S (standard) or L (lower pressure). |
| (blank) | Mounting bracket included. |
| N | No gauge (N) — for a line with a panel gauge already. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached (K). |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR300-15 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR300 · 1/2" · 300 g |
|---|---|
| One size down | GAR200 |
| One size up | GAR400 |
| Add filtration | GAFR300-15 (filter + regulator) |
Set a precise 0.2 MPa for a delicate clamping circuit on an assembly bench, where the 1/2in port feeds multiple small pneumatic fixtures without over-pressuring them.
Regulate atomizing air to a spray gun at 0.15 MPa, keeping the coating consistent even when the main supply fluctuates, since the balanced valve holds the setpoint.
Supply a test rig with a stable 0.3 MPa for air bearings or sensors, where the lower range and fine adjustment prevent accidental over-pressure to sensitive equipment.
Choose the GAR300 body when you need a 1/2in port and a 300 g unit; step down to a GAR200 (170 g) for 1/8in-1/4in ports, or up to a GAR400 (570 g) for 3/8in-1/2in ports with a heavier body. The L type regulates only 0.05-0.4 MPa (7-58 psi), so it suits low-pressure circuits but cannot reach a 0.5-0.6 MPa setpoint - for standard machine pressures, select the S type instead. This model has no gauge (N), so use the line's panel gauge; the mounting bracket is included, and the PT thread reads MPa/psi on any fitted gauge. A reverse-flow (reflux) valve is attached (K). If the line also needs clean air, use a GAFR300-15 or a GAF filter upstream, as this regulator does not filter. The L type's adjustable band of 0.35 MPa is about 2.4x narrower than the S type's 0.85 MPa span, giving finer resolution over low pressures.
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR300-15 filter-regulator as your air-prep needs grow.
The GAR30015LNK is a lower-pressure regulator with a 1/2in port, regulating from 0.05-0.4 MPa (7-58 psi). Maximum supply pressure is 1.0 MPa (145 psi), proof pressure is 1.5 MPa (215 psi), and the temperature range is -20 to 70 C. The unit weighs 300 g, has no gauge, includes a mounting bracket, and uses PT threads.
The N option means no circular pressure gauge is fitted, so you read the pressure on the line's own panel gauge instead. The K option indicates a reverse-flow (reflux) valve is attached to the regulator. This model includes the mounting bracket and uses PT threads with an MPa/psi gauge scale if one is added.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.