The AirTAC Airtac GAR Air Regulator GAR30015SJNK is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.9 MPa range, with 1/2" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.
The GAR30015SJNK is a regulator-only unit that takes a variable supply and holds a steady downstream pressure you set with its knob. It does not filter or dry the air and has no bowl or element; for clean air you need a GAFR or a GAF upstream. This 1/2in model weighs 300 g and regulates from 0.05-0.9 MPa (7-130 psi), making it a standard-pressure choice for medium-demand lines.
Its pressed-in self-locking knob keeps the setpoint from drifting when the machine vibrates, so a calibrated pressure stays put between shifts. With no gauge fitted, you read the pressure on the line's own panel gauge. The reverse-flow (reflux) valve is attached per the K code, and the PT thread gives MPa/psi gauge compatibility.
| Model | Airtac GAR Air Regulator GAR30015SJNK |
|---|---|
| Series | GAR300 air regulator |
| Port size | 1/2" (PT thread) |
| Regulation type | Standard |
| Pressure range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure gauge | None (N) — MPa / psi port |
| Bracket | Not included (J) |
| Reflux valve | Attached (K) |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 300 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR300 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR300 | GA300 series air regulator — sets the port range and weight class. |
|---|---|
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| S | Standard regulation: 0.05 - 0.9 MPa (7 - 130 psi). This body offers S (standard) or L (lower pressure). |
| J | No bracket (J) — panel mount or existing bracket. |
| N | No gauge (N) — for a line with a panel gauge already. |
| (blank) | PT thread; gauge scale MPa / psi. |
| K | Reverse-flow (reflux) valve attached (K). |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR300-15 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR300 · 1/2" · 300 g |
|---|---|
| One size down | GAR200 |
| One size up | GAR400 |
| Add filtration | GAFR300-15 (filter + regulator) |
Set a steady 0.4 MPa for a milling fixture clamp on a CNC table. The self-locking knob holds the setting through spindle vibration, and the 1/2in port feeds the clamp cylinder directly.
Regulate air to a belt tensioner on a packaging line. The 300 g body mounts on the frame rail, and the no-gauge design relies on the line's central panel readout for monitoring.
Provide a stable 0.6 MPa to a pneumatic test fixture on an R&D bench. The balanced design holds the setpoint as shop supply fluctuates, and the reflux valve is fitted for the specified flow direction.
Choose the GAR300 body when your line needs 1/2in ports and a 300 g regulator that mounts on a panel or existing bracket; this J code omits the bracket, so plan for a panel cutout or your own mount. The S type spans 0.05-0.9 MPa (7-130 psi) for standard machinery, while an L type would cap at 0.4 MPa and miss higher setpoints. Since N removes the gauge, verify your panel has one; PT threads pair with MPa/psi scales. The K option adds a reflux valve, and if the air needs cleaning, step up to a GAFR300-15 or add a GAF filter upstream. This S type's adjustable band is about 2.4x the L type's span (0.85 MPa vs 0.35 MPa).
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR300-15 filter-regulator as your air-prep needs grow.
It regulates air from 0.05-0.9 MPa (7-130 psi), with a max supply of 1.0 MPa (145 psi) and proof pressure of 1.5 MPa (215 psi). Operating temperature is -20 to 70 C, and the unit weighs 300 g with a 1/2in port. It is a standard (S) type regulator with no gauge and no bracket.
J means the mounting bracket is not included, so you need a panel mount or your own bracket. N means no pressure gauge is fitted, so you read the downstream pressure on the line's own panel gauge instead of on the regulator.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.