The AirTAC Airtac GAR Air Regulator GAR30015SN is a genuine compressed-air pressure regulator. It sets and holds a steady downstream pressure across the 0.05 - 0.9 MPa range, with 1/2" ports and a no-gauge (N) port for a panel gauge. It regulates pressure only — it does not filter the air or remove water.
The AirTAC GAR30015SN is a regulator-only unit that takes a higher supply pressure and holds a steady, lower downstream pressure you set with its knob. It does not filter the air or remove water, so install a separate GAF or GAFR upstream if the line needs cleaning. This 1/2in model weighs 300 g and regulates in the standard 0.05-0.9 MPa (7-130 psi) band.
Its pressed-in self-locking knob prevents the setpoint from drifting when the machine vibrates, so a calibrated pressure stays put during a shift. The balanced adjustment mechanism also holds the setting as supply pressure varies. With no gauge fitted, read the downstream pressure on the line's own panel gauge.
| Model | Airtac GAR Air Regulator GAR30015SN |
|---|---|
| Series | GAR300 air regulator |
| Port size | 1/2" (PT thread) |
| Regulation type | Standard |
| Pressure range | 0.05 - 0.9 MPa (7 - 130 psi) |
| Pressure gauge | None (N) — MPa / psi port |
| Bracket | Included |
| Reflux valve | None |
| Fluid | Air |
|---|---|
| Max. pressure | 1.0 MPa (145 psi) |
| Proof pressure | 1.5 MPa (215 psi) |
| Temperature range | -20 to +70 °C |
| Adjustment | Self-locking press-in knob |
| Mounting | Panel + optional bracket |
| Weight | 300 g |
Specifications follow the official AirTAC GAR catalogue (pages 228-229). This is a regulator only — it sets and holds a downstream pressure but does not filter the air or separate water. To clean the air as well, use the matching GAFR300 filter-regulator or add a GAF filter upstream. Never run above the 1.5 MPa (215 psi) proof pressure.
| GAR300 | GA300 series air regulator — sets the port range and weight class. |
|---|---|
| 15 | Port size 1/2". This body offers 08 = 1/4", 10 = 3/8", 15 = 1/2". |
| S | Standard regulation: 0.05 - 0.9 MPa (7 - 130 psi). This body offers S (standard) or L (lower pressure). |
| (blank) | Mounting bracket included. |
| N | No gauge (N) — for a line with a panel gauge already. |
| (blank) | PT thread; gauge scale MPa / psi. |
| (blank) | No reverse-flow (reflux) valve. |
A GAR regulates pressure but does not filter — there is no bowl, element or drain code. Need to clean the air too? The matching GAFR300-15 is the same regulator with a built-in filter.
All bodies share the same 0.05-0.9 MPa (S) regulated range, 1.0 MPa max and 1.5 MPa proof; the body number sets the port size and the flow the regulator can pass. Bigger ports feed higher air demand. The catalogue plots a flow curve at 0.7 MPa inlet but prints no numeric envelope, so size by port and weight and confirm the curve for a real duty point.
| This model | GAR300 · 1/2" · 300 g |
|---|---|
| One size down | GAR200 |
| One size up | GAR400 |
| Add filtration | GAFR300-15 (filter + regulator) |
Set a steady 0.4 MPa for a drill feed cylinder on a small machining station, keeping the thrust consistent as shop supply pressure fluctuates.
Feed a 1/2in manifold that supplies several pneumatic screwdrivers, holding a stable 0.6 MPa so each tool gets the same torque.
Regulate air to a leak-test fixture at 0.3 MPa, relying on the self-locking knob to hold the test pressure through repeated cycles.
Choose the GAR300 body for 1/2in ports and a 300 g mass, stepping up from the lighter 170 g GAR200 when the line needs more air. The S type covers 0.05-0.9 MPa (7-130 psi), which suits standard machines; pick the L type only for low-pressure work below 0.4 MPa. This model ships with the mounting bracket included and uses PT threads, whose gauge scale reads MPa/psi. For clean air, pair it with a GAFR300-15 or a GAF filter upstream. The S type's adjustable band is about 2.4x the L type's span.
Quick checklist
This is a regulator only — it sets and holds pressure but does not filter or lubricate. Add a GAF filter, a GAL lubricator, or step up to the GAFR300-15 filter-regulator as your air-prep needs grow.
The GAR30015SN is a standard-type regulator with a 1/2in port and a 300 g weight. It regulates from 0.05-0.9 MPa (7-130 psi), with a max supply pressure of 1.0 MPa (145 psi) and a proof pressure of 1.5 MPa (215 psi). It operates from -20 to 70 C and has no pressure gauge fitted.
The 'N' in the model code means no gauge is fitted, reducing cost and panel space. You read the downstream pressure on the line's own panel gauge or install an AirTAC replacement gauge if needed. The PT thread option means the gauge scale would read MPa/psi.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models usually ship in 3-4 days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT) and destination. We confirm price, stock and lead time — usually within 7-8 hours.