verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC200C06C1K

The AirTAC GC FRL Unit GC200C06C1K is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$83.14 $88.88Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC200C06C1K

GC200C06C1K is a genuine AirTAC G-series three-piece F.R.L. combination: a separate filter, regulator and lubricator working together as one air-treatment station. It strips water and particulate from compressed air, holds the downstream pressure steady and meters oil mist to the tools and cylinders being fed. This 200-size set is specified with PT1/8 ports, a differential-pressure drain, standard 40 um filtration, a round pressure gauge marked in MPa and a reverse (check) valve fitted so downstream air cannot bleed back through the unit if upstream pressure falls.

The G-series covers 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch and PT, G or NPT threads, so a larger set can be specified as the branch grows. Maximum working pressure is 1.0 MPa (145 psi), the standard temperature range is -5 to 70 C (non-freezing), and the PC bowls suit indoor compressor-room duty. Flow is published as curves rather than a single rating, so send us your application and we will confirm the figures and the full datasheet on request.

Airtac GC FRL Unit GC200C06C1K Technical Specifications

ModelAirtac GC FRL Unit GC200C06C1K
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC200C06C1K

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC200C06C1K Is Used

precision_manufacturing

CNC machining cell clamping

Filtering, regulating and lubricating the air feeding pneumatic clamps on a CNC milling cell, with oil mist metered to cylinder seals and directional valves as the clamps cycle all shift.

air

Trim-line paint spray booth

Conditioning the supply to spray guns at an automotive trim-line paint booth, where water carryover or pressure drift would show up directly in the finish.

conveyor_belt

Packaging conveyor actuation

Treating the air that strokes cylinders on a carton-sealing conveyor, protecting pilot valves from particulate and giving maintenance one drain and gauge point to check on rounds.

Is the Airtac GC FRL Unit GC200C06C1K the Right Station?

Sizing starts at the port: this 200-size set carries PT1/8 ports, and the next catalogue steps are GC300, GC400 and GC600, each a size larger with more flow capacity. The differential-pressure drain is the default on this code; automatic (A) and manual (M) drain versions are catalogue options if your maintenance routine or the condensate load calls for them. The 40 um element suits general plant air; choose the W code for 5 um where pilot valves or instrumentation need finer protection. With the differential drain, the regulator set point ranges 0.15-0.9 MPa (20-130 psi), and the round gauge is marked in MPa; psi and bar scale options exist in the catalogue. PT thread is the standard here, with G (BSPP) and NPT available to order. Flow for the G-series is published as curves, not a single rating, so ask us to confirm sizing against the datasheet before you order.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

Airtac GC FRL Unit GC200C06C1K FAQ

AirTAC publishes G-series capacity as flow curves, not a single rated figure, so we deliberately do not quote one number. Tell us your line pressure and the air consumption of the equipment you are feeding, and we will confirm the sizing against the datasheet on request.

The W code swaps the standard 40 um filter element for a 5 um element, which suits finer applications such as instrumentation and sensitive pilot valves. Both drain types, gauge styles and the reverse valve option are separate choices in the catalogue.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC200C06C1K

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06C1K and will confirm price, stock and lead time — usually within 7-8 hours.