verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC200C06F1

The AirTAC GC FRL Unit GC200C06F1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$71.79 $77.26Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC200C06F1

GC200C06F1 is a genuine AirTAC G-series three-piece F.R.L. combination: a separate filter, regulator and lubricator combined into one air-treatment station. It strips water and particulate from compressed air, holds downstream pressure steady and meters oil mist to the equipment being fed. This 200-size set is specified with PT1/8 ports, a differential-pressure drain, standard 40 um filtration and a square pressure gauge marked in MPa mounted with the set.

The G-series is available in 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch and PT, G or NPT threads, so a larger set can be specified as the circuit expands. Maximum working pressure is 1.0 MPa (145 psi), the standard temperature range is -5 to 70 C (non-freezing), and the PC bowls are intended for indoor compressor-room duty. Flow is published as curves rather than a single rating, so share your application and we will confirm the figures and the full datasheet on request.

Airtac GC FRL Unit GC200C06F1 Technical Specifications

ModelAirtac GC FRL Unit GC200C06F1
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC200C06F1

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC200C06F1 Is Used

valve

Pilot-valve air headers

Conditioning air on a header feeding pilot-operated process valves, with the square MPa gauge giving operators a clear set-point check during plant rounds.

conveyor_belt

Parcel-sorter diverters

Treating the air for diverter cylinders on a parcel-sorter conveyor, with 40 um filtration ahead of the solenoid valves and a single drain point for the branch.

engineering

Weld-cell fixture clamps

Supplying filtered, regulated and lubricated air to weld-fixture clamps, with the gauge and regulator letting the cell hold a stable working pressure through the shift.

Is the Airtac GC FRL Unit GC200C06F1 the Right Station?

Port sizing drives the choice: this 200-size set carries PT1/8, with GC300, GC400 and GC600 as the catalogue steps up for heavier branches. The differential-pressure drain is the default on this code; automatic (A) and manual (M) drain versions are catalogue options. The 40 um element is the standard grade for general plant air; choose the W code where 5 um filtration is needed. The F code selects the square gauge in MPa scale, and psi or bar scales are available as catalogue alternatives, as is the round gauge style. PT is the standard thread here, with G (BSPP) and NPT orderable as specifications. Because G-series flow is published as curves rather than a single rating, ask us to confirm sizing against the datasheet before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

Airtac GC FRL Unit GC200C06F1 FAQ

AirTAC publishes G-series capacity as flow curves rather than a single rated figure, so no one number is quoted here. Tell us your operating pressure and the air consumption of the branch, and we will confirm the sizing against the datasheet on request.

The F code specifies the square gauge with an MPa scale. Round-gauge versions exist in the catalogue, and psi or bar scales are alternative ordering options, so you can match the units your maintenance team already reads.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC200C06F1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06F1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.