Airtac GC FRL Unit GC200C06MC1

The AirTAC GC FRL Unit GC200C06MC1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$71.79 $77.26Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC200C06MC1

The GC series is AirTAC's three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator supplied as a set so one point of conditioning removes water and particulate, holds a set downstream pressure and meters a controlled oil mist into the air stream. This GC200C06MC1 is the 200 size with PT1/8 ports, a manually drained filter bowl, the standard 40 um filter element and a round external pressure gauge on the MPa scale. With manual drainage the regulator sets from 0.05 to 0.9 MPa (7-130 psi), and maximum working pressure is 1.0 MPa (145 psi).

This is a genuine AirTAC part. The G series spans 200, 300, 400 and 600 sizes with ports from 1/8 to 1 inch; PT thread is the standard with G (BSPP) and NPT as catalogue options. Filter bowls in this 200 size are polycarbonate (PC), and the temperature range is -5 to 70 C, non-freezing. Other drain types, a 5 um element and alternative gauge scales can be selected within the series. AirTAC publishes flow as curves rather than a single rated figure, so ask us to confirm flow and datasheet details for your application.

Airtac GC FRL Unit GC200C06MC1 Technical Specifications

ModelAirtac GC FRL Unit GC200C06MC1
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC200C06MC1

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC200C06MC1 Is Used

factory

Benchtop carton-sealing machine feed

Cleaning, regulating and lubricating the 1/8-inch air supply that drives the tape-head and flap cylinders on a small packaging bench, with a manual drain that suits a single-shift line.

science

Laboratory sample-handler actuators

Feeding grippers and small slides on laboratory automation, where filtered, oil-misted air at a steady set pressure keeps motion consistent and the manual drain fits a shutdown checklist.

conveyor_belt

Light conveyor gating circuit

Supplying divert and stopper cylinders on a conveyor spur, where one three-unit set keeps water and debris out of the valves, holds the pressure and lubricates the cylinder seals.

Is the Airtac GC FRL Unit GC200C06MC1 the Right Station?

Step up or down through the 200, 300, 400 and 600 sizes to match the port and flow your circuit needs; this unit is the 200 size with PT1/8 ports. The M in the code fixes a manual drain, which also widens the regulator setting range to 0.05-0.9 MPa (7-130 psi); automatic and differential-pressure drain versions set from 0.15-0.9 MPa (20-130 psi). The standard element is 40 um; add W for 5 um. The C1 gauge code fits the round external gauge on the MPa scale, while embedded square gauges and psi or bar scales are catalogue choices. Thread is PT as standard with G (BSPP) and NPT as orderable options, and the bowl on this 200 size is polycarbonate. Because AirTAC publishes flow as curves rather than a single rating, ask us to confirm sizing against your application before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

Airtac GC FRL Unit GC200C06MC1 FAQ

AirTAC publishes G-series performance as flow curves rather than a single rated figure, so we do not quote one number here. Send us your supply pressure, downstream demand and allowable pressure drop and we will confirm sizing from the datasheet on request before you order.

The M in the code means the filter bowl is emptied by hand at intervals you set, which suits enclosures someone visits regularly. It also allows regulator settings down to 0.05 MPa (7 psi); automatic and differential-pressure drain versions set from 0.15 MPa (20 psi) and can be ordered as catalogue options.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC200C06MC1

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06MC1 and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.