The AirTAC GC FRL Unit GC200C06MF1 is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The GC200 series is AirTAC's three-piece F.R.L. combination: a separate air filter, pressure regulator and lubricator built up as one air-preparation set. This GC200C06MF1 configuration has a PT1/8 port, a manual-drain filter bowl, the standard 40 um filtration grade and an embedded square pressure gauge with an MPa scale. In use it removes water and particulate from the compressed air line, holds a steady downstream pressure that you set on the gauge, and meters a controlled oil mist to feed downstream pneumatic cylinders and tools.
This is a genuine AirTAC part. The G-series combination comes in 200, 300, 400 and 600 sizes with ports up to 1 inch, PT / G(BSPP) / NPT thread options, differential-pressure, automatic or manual drains, 40 um or 5 um (W) filter grades and a choice of gauge scales. Max working pressure is 1.0 MPa (145 psi) and the operating range is -5 to 70 C, non-freezing. Flow figures for this unit are published as curves rather than a single rated number, so ask us and we will confirm the datasheet for your application on request.
| Model | Airtac GC FRL Unit GC200C06MF1 |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Feeds impact wrenches and air ratchets at a workshop bench: the filter strips line water, the regulator holds a steady tool pressure and the lubricator meters oil mist to keep the tool motors running.
Prepares the air supply for small gripper and clamp cylinders on a carton packaging conveyor, with the gauge giving operators a visible set pressure and manual drain for end-of-shift blowdown.
Supplies filtered, regulated and lubricated air to a pneumatic clamping fixture on a machining centre, so clamp cylinders receive consistent pressure and film protection cycle after cycle.
At PT1/8 this is the most compact porting in the 200 size, suited to light air consumption; step up to GC300/400/600 for larger ports and higher demand. Because this unit has a manual drain (code M), condensate is released by hand, and the regulator setting range on manual-drain units is 0.05-0.9 MPa (7-130 psi). The 40 um grade is the standard element; choose 5 um (W) for finer protection. The square embedded gauge reads in MPa here, with psi and bar scales available as options, and PT is the standard thread with G and NPT as orderable options. Flow is published as curves, not a single rating, so send us your flow demand and we will confirm sizing against the datasheet before you order.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves rather than a single rated figure, so we do not quote a flow number on the page. Tell us your required flow and working pressure and we will confirm the correct size from the datasheet on request - including stepping you to a 300, 400 or 600 unit if the 200 size at 1/8 inch is too small.
The M in the code means the filter bowl is drained by hand rather than automatically, so an operator opens the drain at intervals to release collected condensate. Manual-drain versions also carry the wider 0.05-0.9 MPa (7-130 psi) regulator setting range, versus 0.15-0.9 MPa (20-130 psi) on automatic and differential-pressure drain versions. If you prefer hands-off draining, ask about the A (automatic) or default differential-pressure versions.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.