AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC200C06MN

The AirTAC GC FRL Unit GC200C06MN is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$66.14 $71.46Save 7% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC200C06MN

The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator piped as one set, so filtration, regulation and oil-mist lubrication are all handled in a single purchase. This 200-size configuration comes with PT1/8 ports, a manual drain on the filter bowl, the standard 40 um filter element, a standard-type regulator and no gauge fitted. Because the drain is manual, the regulator covers 0.05-0.9 MPa (7-130 psi), with a maximum working pressure of 1.0 MPa (145 psi). The 200-size bowl is PC (polycarbonate) and the unit works in temperatures from -5 to 70 C.

This is a genuine AirTAC part. The G series runs from 200 to 600 size, with larger sizes giving larger ports and more flow, plus options including automatic or differential-pressure drains, a 5 um fine filter (W code), a gauge, G (BSPP) or NPT thread, and a reverse/check valve. Flow figures are published as curves rather than a single rating, so ask us to confirm the datasheet for your application before you order.

Airtac GC FRL Unit GC200C06MN Technical Specifications

ModelAirtac GC FRL Unit GC200C06MN
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC200C06MN

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC200C06MN Is Used

air

Spray booth gun feed

Mounted at a small paint or finishing booth, this FRL filters water and grit out of the gun supply, lets the operator set atomisation pressure on the regulator, and meters a light oil mist for any downstream air tools sharing the drop.

handyman

Bench air-tool station

At a maintenance workbench running impact drivers, die grinders and air ratchets, the filter keeps moisture out of the tools, the regulator holds a steady working pressure, and the lubricator feeds a continuous oil mist to extend tool life.

view_module

Small packaging machine

Feeding the cylinders of a carton sealer or small case packer, this unit cleans and dries the supply, holds the pressure the machine was set up at, and lubricates the valves and cylinders as the cycle runs.

Is the Airtac GC FRL Unit GC200C06MN the Right Station?

Keep the 200 size with its PT1/8 ports for lines with modest air demand, and step up to 300, 400 or 600 when you need larger ports and higher flow. The manual drain on this version gives the widest regulating range (0.05-0.9 MPa, 7-130 psi) but needs periodic draining of the bowl; automatic and differential-pressure drain versions remove that chore. The 40 um element is standard, or choose the W option for 5 um filtration. Thread is PT as standard, with G (BSPP) and NPT available as catalogue options, and a bracket or gauge can be specified. Flow is published as curves, not a single rating, so confirm sizing against your application with us before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

Airtac GC FRL Unit GC200C06MN FAQ

AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Send us your application details and we will confirm the flow and datasheet figures for you before you order.

You periodically open the drain to expel collected water, rather than the bowl emptying itself. The upside of the manual-drain version is the widest regulating range, 0.05-0.9 MPa (7-130 psi). If unattended draining matters, ask about the automatic or differential-pressure drain versions.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC200C06MN

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06MN and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.