The AirTAC GC FRL Unit GC200C06MNK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator piped as one set. This 200-size configuration adds the K option, a reverse/check valve, alongside PT1/8 ports, a manual drain on the filter bowl, the standard 40 um filter element, a standard-type regulator and no gauge. With the manual drain, the regulator covers 0.05-0.9 MPa (7-130 psi) and the maximum working pressure is 1.0 MPa (145 psi). The 200-size bowl is PC (polycarbonate) and the working temperature range is -5 to 70 C.
This is a genuine AirTAC part. The G series spans 200 to 600 size with larger ports and more flow at the bigger sizes, plus options such as automatic or differential-pressure drains, a 5 um fine filter (W code), a gauge, G (BSPP) or NPT thread. Flow figures are published as curves rather than a single rating, so ask us to confirm the datasheet for your circuit before ordering.
| Model | Airtac GC FRL Unit GC200C06MNK |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
On a pneumatic clamping fixture, the check valve helps the circuit hold its regulated pressure if the shop supply sags, while the filter keeps moisture out of the clamp cylinders and the lubricator mists the sealing surfaces of the valves.
Feeding an indexing or pick-and-place station, the unit cleans the supply, pins the working pressure for repeatable cylinder strokes, and the check valve prevents downstream loss when the upstream line is vented between cycles.
On a small laboratory or test-bench rig with pneumatic actuators, this set filters and regulates the supply, oils the moving parts, and the check valve stops stored pressure bleeding back into the plant ring main during shutdown.
Choose this K version when the circuit should hold its set pressure if the upstream supply dips, since the fitted reverse/check valve blocks backflow through the set. The 200 size with PT1/8 ports suits modest air demand; step to 300, 400 or 600 for more flow. The manual drain gives the widest regulating range (0.05-0.9 MPa, 7-130 psi) but needs periodic bowl draining; automatic and differential-pressure drains are alternatives. The 40 um element is standard and the W option gives 5 um. Thread is PT as standard, with G (BSPP) and NPT as catalogue options. Flow is published as curves, not a single rating, so confirm sizing with us before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes GC series flow as curves, not as a single rated figure, so no rated number is quoted here. Tell us your duty and we will confirm the flow and datasheet figures for you before you order.
K means a reverse/check valve is fitted, so air will not flow backwards through the set once supply pressure falls. It is useful where the downstream circuit must hold its regulated pressure. This version keeps the manual drain and standard 40 um element.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.