The AirTAC GC FRL Unit GC200C06MNW is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator piped as one set. This 200-size configuration is built with the W option, a 5 um fine filter element instead of the 40 um standard, together with PT1/8 ports, a manual drain on the filter bowl, a standard-type regulator and no gauge. With the manual drain, the regulator adjusts from 0.05 to 0.9 MPa (7-130 psi) and the maximum working pressure is 1.0 MPa (145 psi). The 200-size bowl is PC (polycarbonate) and the unit works from -5 to 70 C.
This is a genuine AirTAC part. The G series runs from 200 to 600 size, with larger ports and more flow at the bigger sizes, and options including automatic or differential-pressure drains, a gauge, G (BSPP) or NPT thread, and a reverse/check valve (K code). Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your application before ordering.
| Model | Airtac GC FRL Unit GC200C06MNW |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
On a CNC machining centre's pneumatic supply for tool-clamp and chip-door actuators, the 5 um element catches finer particles that standard filtration lets through, while the regulator holds the pressure the machine builder specified and the lubricator mists the actuators.
Supplying a manifold of directional control valves on a small automation line, this unit dries and fine-filters the air to protect the valve spools, sets a stable working pressure, and meters lubricant to the downstream cylinders.
On laboratory automation with small pneumatic pushers and grippers, the 5 um filtration keeps fine contamination away from compact actuators, the regulator pins the gentle working pressure, and the lubricator maintains a light oil mist.
Pick this W version when the 40 um standard element is too coarse for the valves or tools downstream; the 5 um element traps finer particles. The 200 size with PT1/8 ports fits modest air demand, and 300, 400 or 600 sizes give more flow. The manual drain offers the widest regulating range (0.05-0.9 MPa, 7-130 psi) but needs regular bowl draining; automatic and differential-pressure drains exist. Thread is PT as standard with G (BSPP) and NPT as catalogue options, and a gauge or bracket can be added. Flow is published as curves, not a single rating, so confirm sizing with us before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes flow for the GC series as curves, not as a single rated figure, so we do not quote a number here. Share your application details and we will confirm the flow and datasheet figures for you before you order.
The W code swaps the standard 40 um element for a 5 um fine filter, which traps finer particles that can upset sensitive valves and compact actuators. It is the right choice where air quality downstream matters; otherwise the 40 um standard keeps differential pressure lower.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.