verified AirTAC China Authorized Export Seller shield 100% Genuine AirTAC Parts workspace_premium 1-Year Warranty
appsShop by Modelexpand_more
person shopping_cart Request a QuoteQuote
AirTAC GC200 · F.R.L. Combination (filter + regulator + lubricator)

Airtac GC FRL Unit GC200C06MNWK

The AirTAC GC FRL Unit GC200C06MNWK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).

  • TypeF.R.L. combination (3 units)
  • Port sizeSee datasheet
  • Regulating range0.15 - 0.9 MPa (20 - 130 psi)
  • Filtering grade40 µm
  • DrainDifferential-pressure drain
  • Bowl materialPC
  • Pressure gaugeFitted
  • ThreadPT
$77.48 $83.09Save 6% Standard model — ready in 3-5 business days to process and dispatch
Request a Quote
  • No minimum order. A single piece can be ordered.
  • Ready in 3–5 business days. That is the time we take to process the order and hand it to the carrier. Transit time after that depends on the destination.
Compare every GC200-06 drain, gauge and thread option on one page All GC200-06 codes →
verified Genuine AirTAC workspace_premium 1-year warranty bolt Reply in 7-8 h

About the Airtac GC FRL Unit GC200C06MNWK

The AirTAC GC series is a three-unit F.R.L. combination: a separate air filter, pressure regulator and lubricator piped as one set. This 200-size configuration combines the W option, a 5 um fine filter element instead of the 40 um standard, with the K option, a reverse/check valve, plus PT1/8 ports, a manual drain on the filter bowl, a standard-type regulator and no gauge. With the manual drain, the regulator covers 0.05-0.9 MPa (7-130 psi) and the maximum working pressure is 1.0 MPa (145 psi). The 200-size bowl is PC (polycarbonate) and the working temperature range is -5 to 70 C.

This is a genuine AirTAC part. The G series spans 200 to 600 size, with larger ports and more flow at the bigger sizes, and further options including automatic or differential-pressure drains, a gauge, and G (BSPP) or NPT thread. Flow is published as curves rather than a single rating, so ask us to confirm the datasheet figures for your circuit before ordering.

Airtac GC FRL Unit GC200C06MNWK Technical Specifications

ModelAirtac GC FRL Unit GC200C06MNWK
SeriesGC200 F.R.L. combination
CompositionFilter + regulator + lubricator (3 units)
Port sizeSee datasheet (PT thread)
Filtering grade40 µm
Regulating range0.15 - 0.9 MPa (20 - 130 psi)
Pressure typeStandard type
FluidCompressed air
Max. working pressure1.0 MPa (145 psi)
Temperature range-5 to +70 °C (unfreeze)
Drain typeDifferential-pressure drain
Bowl materialPC
Pressure gaugeFitted — factory standard, Factory standard scale
Reflux valveNot fitted

Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.

Model Code: Airtac GC FRL Unit GC200C06MNWK

GC200G-series F.R.L. combination, 200 body — sets the port range.
C0Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4".
(blank)Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)).
(blank)Standard type. Blank is standard, L is the low-pressure type.
(blank)Pressure gauge fitted (blank).
(blank)Gauge shape: Factory standard. C is round, F is square.
(blank)Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar.
(blank)Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist.
(blank)PT thread. PT is the default; G is BSPP and T is NPT.
(blank)No reverse-flow valve (the default).

Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.

Size Class & How It Differs From GFC

  • GC200PT1/8" - PT1/4"
  • GC300PT1/4" - PT1/2"
  • GC400PT3/8" - PT1/2"
  • GC600PT3/4" - PT1"

A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.

This modelGC200 · See datasheet · 40 µm
One size upGC300
Two-unit equivalentGFC200-C0
Build orderFilter → regulator → lubricator

Where the Airtac GC FRL Unit GC200C06MNWK Is Used

shield

Fine-filtered clamp circuit

On a pneumatic clamp circuit with compact cylinders, the 5 um element protects the small control valves, the regulator pins the clamping pressure, and the check valve helps the clamps hold position if the plant supply drops.

precision_manufacturing

CNC tool-clamp supply

Feeding a machining centre's tool-clamp and air-blast circuit, this set fine-filters the supply to the machine's standard, holds the builder's set pressure, and the check valve stops the machine's stored air bleeding back when the shop main is isolated.

engineering

Assembly press fixtures

On a light pneumatic assembly press with position-sensitive fixtures, the unit delivers clean, finely filtered air, regulates the pressing force via pressure, and the check valve safeguards the set pressure against upstream fluctuations.

Is the Airtac GC FRL Unit GC200C06MNWK the Right Station?

This version stacks two real choices: the W 5 um fine filter for cleaner air to sensitive downstream components, and the K reverse/check valve so the circuit holds its set pressure if the supply dips. The 200 size with PT1/8 ports suits modest air demand; 300, 400 and 600 sizes carry more flow. The manual drain gives the widest regulating range (0.05-0.9 MPa, 7-130 psi) but needs periodic bowl draining; automatic and differential-pressure drains are alternatives. Thread is PT as standard, with G (BSPP) and NPT as catalogue options. Flow is published as curves, not a single rating, so confirm sizing with us before ordering.

Quick checklist

  • ✓ Body size for your peak flow (See datasheet here)
  • ✓ Element 40 µm or 5 µm
  • ✓ Drain sets the regulating band
  • ✓ Gauge fitted, shape and scale
  • ✓ Three-unit (GC) or two-unit (GFC) layout
  • ✓ Oil mist acceptable downstream
Ask an Engineer

Installation & Maintenance Notes

  • check Install with the airflow arrow: filter first, lubricator last.
  • check Mount vertically, bowls down.
  • check Keep inlet pressure at or below 1.0 MPa (145 psi).
  • check Adjust only within 0.15 - 0.9 MPa (20 - 130 psi).
  • check Drain condensate before the bowl fills; check the oil level.
  • check Keep the station above freezing (-5 to +70 °C, unfreeze).

The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.

Airtac GC FRL Unit GC200C06MNWK FAQ

AirTAC publishes GC series flow as curves, not as a single rated figure, so no rated number is quoted here. Tell us your application and we will confirm the flow and datasheet figures for you before you order.

W upgrades the filter from the standard 40 um element to a 5 um fine element, and K fits a reverse/check valve so air cannot flow back through the set when supply pressure falls. Both are combined here on the manual-drain, no-gauge 200-size unit with PT1/8 ports.

verified

Authorized Export Seller

Genuine AirTAC parts produced by AirTAC factory.

workspace_premium

1-Year Warranty

Covers non-human-caused product damage.

local_shipping

Fast Dispatch

Standard models are processed and dispatched in 3-5 business days.

bolt

Fast Reply

Most inquiries answered within 7-8 hours.

Request a Quote for Airtac GC FRL Unit GC200C06MNWK

Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.

Thank you. We received your request for GC200C06MNWK and will confirm price, stock and lead time — usually within 7-8 hours.

For the fastest response, keep the complete model number above and include a clear photo of the product label. If photo upload is unavailable, email photos to [email protected] with your model number.