The AirTAC GC FRL Unit GC200C06NK is a genuine G-series three-unit F.R.L. combination: a separate filter, a separate regulator and a separate lubricator assembled as one air-preparation station. It has See datasheet ports, a 40 µm element, a differential-pressure drain and regulates 0.15 - 0.9 MPa (20 - 130 psi).
GC200C06NK is an AirTAC G-series three-unit F.R.L. combination - separate filter, regulator and lubricator in one set - with the K option adding a reverse (check) valve. This version is the size 200 frame with PT1/8 ports, a differential-pressure drain on the filter bowl, the standard 40 um filter element and no gauge (the trailing N). Maximum working pressure is 1.0 MPa (145 psi), service temperature is -5 to 70 C, non-freezing, and at size 200 the filter and lubricator bowls are PC (polycarbonate).
This is a genuine AirTAC part. The G series also spans sizes 300, 400 and 600, with automatic or manual drain options, a 5 um filter element (W), gauge variants with MPa, psi or bar scales, and G (BSPP) or NPT threads orderable instead of the PT standard. Regulator adjustment for this differential-drain set is 0.15-0.9 MPa (20-130 psi). Flow is published as curves rather than a single rating, so we confirm datasheet figures on request.
| Model | Airtac GC FRL Unit GC200C06NK |
|---|---|
| Series | GC200 F.R.L. combination |
| Composition | Filter + regulator + lubricator (3 units) |
| Port size | See datasheet (PT thread) |
| Filtering grade | 40 µm |
| Regulating range | 0.15 - 0.9 MPa (20 - 130 psi) |
| Pressure type | Standard type |
| Fluid | Compressed air |
|---|---|
| Max. working pressure | 1.0 MPa (145 psi) |
| Temperature range | -5 to +70 °C (unfreeze) |
| Drain type | Differential-pressure drain |
| Bowl material | PC |
| Pressure gauge | Fitted — factory standard, Factory standard scale |
| Reflux valve | Not fitted |
Specifications follow the official AirTAC G-series air-preparation data. The regulating band is set by the drain type: automatic and differential-pressure drains regulate 0.15 - 0.9 MPa, a manual drain regulates 0.05 - 0.9 MPa. Standard type, regulating 0.15 - 0.9 MPa (20 - 130 psi). The combination has no separate bracket code — the three units couple together with their own mounting hardware. Flow curves, weight and outline dimensions are not published in our data set — ask us and we will confirm from the factory datasheet.
| GC200 | G-series F.R.L. combination, 200 body — sets the port range. |
|---|---|
| C0 | Port size See datasheet. This body offers 06 = PT1/8", 08 = PT1/4". |
| (blank) | Drain: Differential-pressure drain — this also sets the regulating band (0.15 - 0.9 MPa (20 - 130 psi)). |
| (blank) | Standard type. Blank is standard, L is the low-pressure type. |
| (blank) | Pressure gauge fitted (blank). |
| (blank) | Gauge shape: Factory standard. C is round, F is square. |
| (blank) | Gauge scale: Factory standard. 1 is MPa, 2 is psi, 3 is bar. |
| (blank) | Filtering grade 40 µm. Only 40 µm (blank) and 5 µm (W) exist. |
| (blank) | PT thread. PT is the default; G is BSPP and T is NPT. |
| (blank) | No reverse-flow valve (the default). |
Field order is size, port, drain, type, gauge, shape, scale, grade, thread, reflux — there is no bracket position on a combination. Constituent units, orderable separately as spares: GF200-C0 filter, GR200-C0 regulator and GL200-C0 lubricator.
A GC is three separate units, so the filter and the regulator can each be serviced or replaced on their own. A GFC is the two-unit set, where filtering and regulating share one body — shorter, but the two functions come as one part. Both filter, regulate and lubricate.
| This model | GC200 · See datasheet · 40 µm |
|---|---|
| One size up | GC300 |
| Two-unit equivalent | GFC200-C0 |
| Build order | Filter → regulator → lubricator |
Supplies filtered, regulated, lubricated air to compact benchtop press and clinch stations on 1/8in circuits, with the check valve holding the downstream side of the set.
Conditions the air feeding stopper and pusher cylinders on small indexing conveyors for vials, cartons or electronics trays.
Forms a compact conditioned-air drop at maintenance benches, giving lubricated air for hand-held tools and regulated supply for test fittings.
Choose this K version over the plain GC200C06N when your circuit needs a reverse (check) valve in the set. Stay at size 200 for 1/8in circuits; move to 300, 400 or 600 for 1/4in to 1in ports and higher demand. The differential-pressure drain here suits the standard 0.15-0.9 MPa regulation span, with automatic and manual-drain versions available. The 40 um element is the general-shop-air choice; the 5 um W element (as in GC200C06NWK) is the finer option. Thread is PT as standard, with G (BSPP) and NPT orderable. Because G-series flow is published as curves rather than a single rating, ask us to confirm sizing before ordering.
Quick checklist
The PC bowls must not be cleaned with solvents — wipe them with a dry cloth. The lubricator adds an oil mist downstream of the regulator. If any branch of the line must stay oil-free, take that branch off before the lubricator, or use a GR200-C0 regulator with a GF200-C0 filter on that branch.
AirTAC publishes G-series flow as curves rather than a single rated figure, so we do not quote a number here. Tell us your application's flow demand and we will confirm the datasheet curves against it before you order.
K indicates that a reverse (check) valve is fitted in this set; the plain GC200C06N is supplied without one. Everything else in the decode is unchanged: PT1/8 ports, differential-pressure drain, 40 um element, no gauge.
Genuine AirTAC parts produced by AirTAC factory.
Covers non-human-caused product damage.
Standard models are processed and dispatched in 3-5 business days.
Most inquiries answered within 7-8 hours.
Send us the quantity, thread type (PT / G / NPT), gauge scale and destination. We confirm price, availability and lead time — usually within 7-8 hours.